OM-4418 Page 18
5-4.
Connecting To Weld Output Terminals
803 469-D / 226 005 / 803 778-A
1
AC Weld Output Terminals
Connect work and electrode cables
to weld terminals. (Polarity does not
matter for AC welding.)
!
Failure to properly connect
weld cables may cause ex-
cessive heat and start a fire,
or damage your machine.
2
Weld Output Terminal
3
Supplied Weld Output
Terminal Nut
4
Weld Cable Terminal
5
Copper Bar
Remove supplied nut from weld
output terminal. Slide weld cable
terminal onto weld output terminal
and secure with nut so that weld
cable terminal is tight against cop-
per bar.
Do not place anything be-
tween weld cable terminal and
copper bar. Make sure that the
surfaces of the weld cable termi-
nal and copper bar are clean.
Tools Needed:
3/4 in
1
5
3
4
Do not place
anything between
Correct Installation
Incorrect Installation
2
weld cable terminal
and copper bar.