beautypg.com

4. connecting to weld output terminals – Hobart Welding Products CHAMPION 4500 OM-4418 User Manual

Page 22

background image

OM-4418 Page 18

5-4.

Connecting To Weld Output Terminals

803 469-D / 226 005 / 803 778-A

1

AC Weld Output Terminals

Connect work and electrode cables

to weld terminals. (Polarity does not

matter for AC welding.)

!

Failure to properly connect
weld cables may cause ex-
cessive heat and start a fire,
or damage your machine.

2

Weld Output Terminal

3

Supplied Weld Output

Terminal Nut

4

Weld Cable Terminal

5

Copper Bar

Remove supplied nut from weld

output terminal. Slide weld cable

terminal onto weld output terminal

and secure with nut so that weld

cable terminal is tight against cop-

per bar.

Do not place anything be-

tween weld cable terminal and
copper bar. Make sure that the
surfaces of the weld cable termi-
nal and copper bar are clean.

Tools Needed:

3/4 in

1

5

3

4

Do not place

anything between

Correct Installation

Incorrect Installation

2

weld cable terminal

and copper bar.

This manual is related to the following products: