beautypg.com

Section 7 − operating auxiliary equipment, 1. generator power panel receptacles – Hobart Welding Products CHAMPION 4500 OM-4418 User Manual

Page 27

background image

OM-4418 Page 23

SECTION 7 − OPERATING AUXILIARY EQUIPMENT

.

The welding generator provides power while welding and with the Amperage control in any position. However, under these conditions equipment
connected to the welding generator may be subject to larger than normal voltage fluctuations. It is recommended that only lamps be powered under
these conditions.

7-1.

Generator Power Panel Receptacles

!

Use GFCI-protected extension
cord.

.

Generator power decreases as weld
current increases.

Set Amperage control at max. for full
generator power.

1

240 V 20 A AC Duplex Receptacle
RC1

RC1 supplies 60 Hz single-phase power at

weld/power speed. Maximum output is 4

kVA/kW.
2

120 V 20 A AC Duplex Receptacle

RC2

RC2 supplies 60 Hz single-phase power at

weld/power speed. Maximum output from

RC2 is 2.4 kVA/kW.
3

Supplementary Protector CB1

CB1 protects the receptacles from over-

load. If CB1 opens, the receptacles do not

work.

.

Place switch in the On position to re-
set. If supplementary protector contin-
ues to open, contact Factory
Authorized Service Agent.

Combined output of all receptacles limited

to 4 kVA/kW rating of the generator (See

Section 11 − Generator Power Guide-

lines).
EXAMPLE: If 15 A is drawn from the 120

volt duplex receptacle, only 9 A is available

from the 240 V duplex receptacle.
(120 V x 15 A) + (240 V x 9 A) = 4 kVA/KW.

226 005

2

1

3

This manual is related to the following products: