5-2.

Grounding Generator When Supplying Building Systems

GND/PE

1

2

2

3

800 576-B

!

Ground generator to sys-
tem earth ground if supply-
ing power to a premises
(home, shop, farm) wiring
system.

1

Equipment Grounding

Terminal

2

Grounding Cable

Use #10 AWG or larger insulated

copper wire.
3

Ground Device

.

Use ground device as stated
in electrical codes.

Open/On

1

Closed/Off

5-3.

Engine Prestart Checks

803 468-D

Full

Gasoline

1/2 in

(13 mm)

Check all fluids daily. Engine must

be cold and on a level surface. Unit

is

shipped with 10W30 engine oil.

Engine stops if oil level gets too low.
1

Fuel Valve

Open valve.

.

Close fuel valve before moving
unit or carburetor may flood
and make starting difficult.

Fuel

Add fresh fuel before starting

engine the first time . Fill fuel tank up

to 1/2 in. (13 mm) from top to allow

room for expansion. Check fuel lev-

el on a cold engine before use each

day.

Oil

After fueling, check oil with unit on

level surface. If oil reservoir is not

full, add oil until oil nearly overflows

at oil fill.

.

This unit has a low oil level
shutdown switch to prevent
starting an engine that is low on
oil. However, some conditions
may cause engine damage be-
fore the engine shuts down.
Check oil level often and do not
use the low oil level shutdown
system to monitor oil level.

.

To improve cold weather start-
ing, use correct grade oil for
cold weather (see engine own-
er’s manual).

.

Always close fuel valve after
stopping unit. Moving unit
with fuel valve open may
cause carburetor flooding
and make starting difficult.

This manual is related to the following products: