Section 5 − installation, 1. installing welding generator – Hobart Welding Products CHAMPION 4500 OM-4418 User Manual
Page 20
![background image](/manuals/88842/20/background.png)
OM-4418 Page 16
SECTION 5 − INSTALLATION
5-1.
Installing Welding Generator
Ref install1 8/06 − Ref. 151 556 / 158 936-A / 803 467-C / S-0854
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
Movement
Airflow Clearance
Location
!
Always securely fasten welding
generator onto transport vehicle
or trailer and comply with all
DOT and other applicable codes.
!
Do not install unit where air
flow is restricted or engine
may overheat.
GND/PE
2
3
1
!
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Metal Vehicle Frame
2
Equipment Grounding
Terminal
3
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
.
Electrically bond generator
frame to vehicle frame by met-
al-to-metal contact.
!
If unit does not have GFCI
receptacles, use GFCI-
protected extension cord.
!
Bed liners, shipping skids,
and some running gear insu-
late the welding generator
from the vehicle frame. Al-
ways connect a ground wire
from the generator equip-
ment grounding terminal to
bare metal on the vehicle
frame as shown.
Grounding