beautypg.com

3. servicing air cleaner – Hobart Welding Products CONTRACTOR 3225D User Manual

Page 30

background image

OM-480 Page 26

7-3.

Servicing Air Cleaner

aircleaner4 9/99– 802 495 / Ref. S-0698-B

Y

Stop engine.

1

Air Cleaner

2

Service Indicator (Optional)

3

Window

4

Reset Button

Service air cleaner element if red
band appears in window. A green
band means air cleaner is okay.
Press button to reset indicator.

Y

Do not run engine without air
cleaner or with dirty element.

Clean or replace element if dirty or
damaged. Replace element yearly
or after six cleanings.

5

Dust Ejector

6

Dust Cover

7

Element

8

Safety Element (Optional)

9

Body

To Clean air filter:

Wipe off cover and body. Remove
cover and dump out dust. Wipe dust
from inside cover and body with
damp cloth. Remove element(s)
and reinstall cover.

Y

Do not clean housing with air
hose.

Clean element(s) with compressed
air only. Keep nozzle at least 1 in
(25 mm) from inside of element.
Max. air pressure: 100 psi (690
kPa). Replace element(s) if it has
holes or damaged gaskets.

Reinstall element(s) and cover
(dust ejector down)

2

3

4

1

Blow

Inspect

5

6

7

9

8