Hmr4007, Specifications – Honeywell HMR4007 User Manual
Page 3
HMR4007
SENSOR PRODUCTS
SPECIFICATIONS
Characteristics
Conditions
Min
Typ
Max
Units
General
Accuracy
0.2
0.1
mm
Resolution
0.1
mm
Hysteresis
0.01
mm
Repeatability
0.01
0.1
mm
Update Rate
10
30
Hz
Standoff
Distance (gap) between the target
magnet and the sensor board
0.1
5
(note 1)
mm
Magnetic Field
Range
magnetic field at the sensor array
80
(note 1)
gauss
length
apparent magnet length at sensor array
23
(note 3)
mm
Orientation
Axial
(note 2)
Electrical
Input Voltage
Unregulated
6
28
VDC
Current
15
20
mA
Digital Interface
Baud Rate
nonstandard synchronous serial interface
1000
21,000
Bits / sec.
Signaling Level
TTL levels
( “1” )
( “0” )
3.5
-0.3
5.0
1.5
VDC
VDC
Connector
In-Line 6-Pin Block (0.1” spacing)
Analog Interface
Analog Output
D/A output
0
2.5
VDC
Update Rate
10
30
Hz
Signaling Level
TTL levels
( “1” )
( “0” )
3.5
-0.3
5.0
1.5
VDC
VDC
Connector
In-Line 4-Pin Block (0.1” spacing)
Physical
Dimensions
Circuit Board Assembly
(including connectors)
40.0 x 80.0 x
12.0
mm
Weight
HMR4007
16.5
grams
Environment
Temperature
Operating
Storage
-40
-55
-
-
+70
+125
°C
Note 1: The standoff distance between the sensor board and the target magnet is highly variable. A magnet of sufficient strength,
however, must be used to maintain a magnetic field strength of 80 gauss (min.) at the sensor array and an apparent
magnet length of 23 mm.
Note 2: Sensor boards are factory calibrated in the axial mode using a 27mm cylindrical magnet. Operation in the radial mode
must be configured by the user.
Note 3: cf. "Magnet Considerations" (pg. 8)
Solid State Electronics Center
•
www.magneticsensors.com
•
(800) 323-8295
•
Page 3