HMR4007

SENSOR PRODUCTS

SPECIFICATIONS

Characteristics

Conditions

Min

Typ

Max

Units

General

Accuracy

0.2

0.1

mm

Resolution

0.1

mm

Hysteresis

0.01

mm

Repeatability

0.01

0.1

mm

Update Rate

10

30

Hz

Standoff

Distance (gap) between the target
magnet and the sensor board

0.1

5

(note 1)

mm

Magnetic Field
Range

magnetic field at the sensor array

80

(note 1)

gauss

length

apparent magnet length at sensor array

23

(note 3)

mm

Orientation

Axial

(note 2)

Electrical
Input Voltage

Unregulated

6

28

VDC

Current

15

20

mA

Digital Interface
Baud Rate

nonstandard synchronous serial interface

1000

21,000

Bits / sec.

Signaling Level

TTL levels

( “1” )
( “0” )

3.5

-0.3

5.0
1.5

VDC
VDC

Connector

In-Line 6-Pin Block (0.1” spacing)

Analog Interface
Analog Output

D/A output

0

2.5

VDC

Update Rate

10

30

Hz

Signaling Level

TTL levels

( “1” )
( “0” )

3.5

-0.3

5.0
1.5

VDC
VDC

Connector

In-Line 4-Pin Block (0.1” spacing)

Physical
Dimensions

Circuit Board Assembly

(including connectors)

40.0 x 80.0 x

12.0

mm

Weight

HMR4007

16.5

grams

Environment
Temperature

Operating

Storage

-40
-55

-
-

+70

+125

°C

Note 1: The standoff distance between the sensor board and the target magnet is highly variable. A magnet of sufficient strength,

however, must be used to maintain a magnetic field strength of 80 gauss (min.) at the sensor array and an apparent
magnet length of 23 mm.

Note 2: Sensor boards are factory calibrated in the axial mode using a 27mm cylindrical magnet. Operation in the radial mode

must be configured by the user.

Note 3: cf. "Magnet Considerations" (pg. 8)

Solid State Electronics Center

www.magneticsensors.com

(800) 323-8295

Page 3