Circuit breaker panel, Adjusting brush height, Operation – HP Concorde 608349 User Manual
Page 9: Home find... go to
OPERATION
Concorde
t
HP Plus (01–00)
9
5. Before reaching end of cleaning path, turn pump
switch off and continue to drive machine forward
to extract solution.
6.
Drain recovery tank when recovered water
reaches “FULL LINE” label, located on standpipe
in recovery tank (See DRAINING TANKS).
7.
Observe gallon marker for remaining cleaning
solution.
8.
Periodically check battery meter discharge level.
Recharge batteries when discharged below half.
9.
When solution tank runs dry, turn off pump and
vacuum switches, raise brush and transport
machine to draining area
(See DRAINING
TANKS).
10. If cleaning path leaves streaks, spray tip cleaning
is required (See SPRAY BAR AND SPRAY TIP
MAINTENANCE).
11. If machine is left unattended, turn off machine and
pull out main circuit breaker button.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine
and pull out main circuit breaker button.
CIRCUIT BREAKER PANEL
The machine is equipped with (3) resetable circuit
breakers to protect machine from damage, (labeled as
brush, main and drive). They stop current flow when
circuit overload occurs. Once a circuit breaker has
tripped, determine problem, let motor cool down and
manually reset breaker by pressing circuit breaker
button. The vacuum motors are thermally protected
and will automatically shut–off when an overload
occurs. The main and drive circuit breakers are
designed so you can stop current flow by manually
pulling out circuit breaker buttons. Pull out the main
circuit breaker button when servicing machine or when
machine is left unattended. Circuit breaker buttons are
located at rear of machine as shown (Figure 15).
FIG. 15
ADJUSTING BRUSH HEIGHT
1.
Turn all switches off.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine
and pull out main circuit breaker button.
2.
Disengage brush lift lever from lock block
(Figure 16).
FIG. 16
3.
Locate adjustment knobs on adjustment shaft and
loosen bottom knob (Figure 17).
FIG. 17
4.
Turn upper knob clockwise to lower brush and
counterclockwise to raise.
5.
Tighten down bottom knob after adjusting.
Home
Find...
Go To..