beautypg.com

Machine setup, Filling solution tank, Machine operation – HP Concorde 608349 User Manual

Page 6: Pre–operation checks, Transporting machine, Operation, Home find... go to

background image

OPERATION

6

Concorde

t

HP Plus (01–00)

4. Connect cables to battery posts in numerical order

as labeled (RED to POSITIVE & BLACK to
NEGATIVE). Cover post with rubber boot
(Figure 3).

1

2

3

4

RED (+)

BLK

(–)

FIG. 3

5.

Double check cable connections before closing up
battery compartment.

6. Replace hood and reset the main circuit breaker

button.

7.

Turn main power switch on, and check battery
meter charge level to ensure batteries are fully
charged. If batteries need charging, see
BATTERY CHARGING.

MACHINE SETUP

FILLING SOLUTION TANK

1.

Transport machine to filling station (See
MACHINE OPERATION).

2. Fill solution tank with 113.5 L (30 gal) of clean

water at fill port, 60

°

C (140

°

F) maximum

temperature.

Use gallon markers on side of tank

to indicate fill level (Figure 4).

FIG. 4

NOTE: If filling with a bucket be certain that bucket is
clean. This will prevent possible solution line clogs.

3.

Add recommended cleaning chemical. Use proper
dilution ratio instructions on bottle.

FOR SAFETY: When using machine, follow mixing
and handling instructions on chemical containers.

WARNING: Flammable materials can cause

an explosion or fire. Do not use flammable
materials in tank(s).

ATTENTION: Use only recommended cleaning
chemicals, DO NOT use substitutes. Consult an
authorized distributor to assist you with the
recommended cleaning chemicals.

MACHINE OPERATION

FOR SAFETY: Do not operate machine unless
operator manual is read and understood.

PRE–OPERATION CHECKS

1.

Vacuum floor and remove debris.

2.

Check battery meter charge level; machine
should be fully charged prior to using. Do not
operate machine if batteries are discharged below
half (See BATTERY CHARGING).

3.

Check that recovery tank standpipe screen is in
place.

4.

Check that spray bar is installed (See SPRAY
BAR AND SPRAY TIP MAINTENANCE).

5.

Check that inline strainer filter is installed (See
SOLUTION FILTERS MAINTENANCE).

6.

Inspect spray tips for proper spray pattern (See
SPRAY BAR AND SPRAY TIP MAINTENANCE).

TRANSPORTING MACHINE

Operating machine without using cleaning functions.

1.

Raise brush lift lever and engage lock block.

2.

Activate main power switch.

3.

Press drive switch towards transport mode symbol
(Figure 5).

Home

Find...

Go To..