Draining solution tank, Battery charging, Operation – HP Concorde 608349 User Manual
Page 11: Home find... go to
OPERATION
Concorde
t
HP Plus (01–00)
11
FIG. 21
4.
Remove recovery tank dome and use a hose to
rinse out recovery tank. Be careful not to spray
water into standpipe screen.
5. Replace drain hose plug tightly when tank is
empty.
DRAINING SOLUTION TANK
To drain unused solution from solution tank, pumpout
hose is required (Supplied with machine).
1.
Connect pumpout hose to accessory tool coupler
at rear of machine (Figure 22).
FIG. 22
2.
Hold hose over floor sink or remove recovery
tank dome and direct hose into tank.
3.
Activate main power and pump switch.
BATTERY CHARGING
The following charging instructions are intended
for chargers supplied with machine. Use a battery
charger with the following specifications to
prevent battery damage.
CHARGER SPECIFICATIONS:
S
OUTPUT VOLTAGE – 36 VOLTS
S
OUTPUT CURRENT – 25 AMPS
S
AUTOMATIC SHUT–OFF CIRCUIT
S
FOR LEAD ACID DEEP CYCLE BATTERY CHARGING
NOTE: Recharge batteries ONLY after a total of 30
minutes or more. This will prolong battery life. Never
leave batteries discharged for lengthy periods.
WARNING: Batteries emit hydrogen gas.
Explosion or fire can result. Keep sparks and
open flame away. Keep battery compartment open
when charging.
FOR SAFETY: When servicing machine, wear
protective gloves when handling batteries and
battery cables. Avoid contact with battery acid.
1.
Transport machine to a well–ventilated area for
charging.
2.
Turn main power switch off.
3.
Remove battery compartment hood to access
batteries
(Figure 23).
FIG. 23
Home
Find...
Go To..