beautypg.com

Cool mode, Dehumidification mode – Electrolux U31175 LU4 9QQ User Manual

Page 16

background image

Install the exhaust hose (see page 7-8, turn the drainage

nozzle to the CLOSE position, and check the drainage

nozzle is covered with the stopcock.

1. Press the MODE button to select COOL mode.

. Press the ON/OFF button to start operation.

• The red OPERATION lamp on the unit will illuminate.

Make sure they are securely attached.

3. Press the TEMPERATURE button to set the desired

temperature.

• The temperature can be set within the range of

18°C to 3°C.

4. Press the FAN button to set the desired fan speed.

To turn off

Press the ON/OFF button again.

• The red OPERATION lamp on the unit will turn off.

NOTES:

• To minimise noise it is recommended that during cooling

mode the drainage nozzle should remain in the CLOSE

position.

• To prevent water saturation ensure that stopcocks are

always fitted when not using separate drainage.

Cool mode

In this mode, the air conditioner dehumidifies the room

1. Remove the exhaust hose (see page 7-8).

. Turn the drainage nozzle to the OPEN position.

3. Pull the stopcock (upper) out from the drainage nozzle.

• When the stopcock (upper) is removed, a small amount

of water may be discharged from the drainage nozzle.

• Always perform this procedure with the unit turned

off. Drain water will squirt out if attempted during

operation.

4. Insert the hose clamp into a standard commercially-

available hose (1.7mm inner diameter, 16.7mm outer

diameter).

5. Attach the hose to the drainage nozzle, and secure it

with the hose clamp.

• Depending on room condition, approximately 8

litres of water per day (4 hours) will be dehumidified.

Prepare some kind of bucket of appropriate size to

collect drain water, or take some appropriate measure

to drain the water outside of the room, so that drain

water will not overflow or soak your room.

• Set the hose sloping downwards for easier drainage.

Moreover, do not bend the hose at any point, nor allow

the end to be submerged in water.

Drainage nozzle

Stopcock (Upper)

“CLOSE position”

1

4

2

3

COOL

AUTO QUIET

LOW

HIGH

DEHUM

FAN

VENT

Drainage nozzle

Stopcock (Upper)

“CLOSE position”

1

4

2

3

COOL

AUTO QUIET

LOW

HIGH

DEHUM

FAN

VENT

Drainage nozzle

Stopcock (Upper)

“CLOSE position”

1

4

2

3

COOL

AUTO QUIET

LOW

HIGH

DEHUM

FAN

VENT

COOL

DEHUM

FAN

VENT

COOL

DEHUM

FAN

VENT

COOL DEHUM

FAN

VENT

COOL DEHUM

FAN

VENT

Dehumidification mode

Drainage nozzle

Stopcock (Upper)

Hose clamp

Drain hose

COOL

“OPEN position”

DEHUM

FAN

VENT

7

6

Drainage nozzle

Stopcock (Upper)

Hose clamp

Drain hose

COOL

“OPEN position”

DEHUM

FAN

VENT

7

6

Drainage nozzle

Stopcock (Upper)

Hose clamp

Drain hose

COOL

“OPEN position”

DEHUM

FAN

VENT

7

6

electrolux EXP09CS1WI installation of window kit 13