Installing the Flexible Conduit
Remove the conduit connection plate from the rear of the drawer body, and flip it as shown. (Use the 1⅛" hole.)
1⅛"
1⅛"
1⅜"
1⅜"
1.
Prepare the conduit cord (Figure 1).
2.
Install the conduit cord (Figure 2).
1"
1"
⅜"
⅜"
3½"
3½"
3 wire
4 wire
Figure 1
Figure 2
Knockout surface
Ring
Body
Strain relief
Conduit connection plate
Conduit installations: Insert the strain relief (not included) in the 1⅛"conduit hole, thread the conduit cord through
the body of the strain relief, and fasten the ring, then reinstall the bracket.
Installing a 3-wire Conduit
•
Aluminum building wire may be used but must be rated for the correct amperage and voltage. Connect wires
according to Step 4 depending on the number of wires.
•
Wire used, location/enclosure of splices, etc., must follow good wiring practices and local codes.
Ground strap
Wire tips
Neutral terminal
Black
Black
White
White
Red
Red
1.
Loosen the three lower screws on the terminal block.
2.
Insert the white/neutral bare wire tip through the
bottom-center block opening. (Some models: the wire
inserted through the ground-strap opening into the
bottom-center block opening.)
3.
Insert the left and right wire tips into their
respective block openings.
4.
Tighten the screws to 35 – 50 in.-lbs.
(Any tighter may damage the wires.)