Gas and Electrical Service
•
See below for the recommended location of the gas inlet and electrical junction box/receptacle.
Existing utilities may be used if they are compatible with this range. Check local building codes for allowed
gasvalve locations.
•
An external manual shut-off valve must be installed between the gas inlet and range so the range's gas
supply can be turned on/off. Installation must allow access to the gas shut-off valve when the unit is
installed and access to the remote circuit-breaker panel/fuse box without moving the range.
•
The gas-supply piping and shut-off valve, and the electrical junction box/receptacle must be located so as
not to interfere with the range when it is installed.
•
The junction box and gas-shut off valve must be located so the range can be pulled out for service without
being disconnected.
Model
D
E
F
G
DOP36C86D**
8 7/8" (22.5 cm)
6 5/8" (16.8 cm)
11 3/16" (28.4 cm)
24 1/4" (61.6 cm)
DOP48C86D**
5 1/2" (13.9 cm)
6 5/8" (16.8 cm)
8 1/8" (20.6 cm)
26 5/8" (67.6 cm)
Recommended
position for
Gas stub
Recommended
position for
electrical outlet
G
E
D
F