CUTOUT DIMENSIONS

Range Model

A

B

C

DOP36C86D**

42” (106.7 cm)*;

36” (91.4 cm)**

36” (91.4 cm)**;

36 1/8” (91.7 cm)***

33 1/2” (84.8 cm)

DOP48C86D**

54” (137.2 cm)*;

48” (121.9 cm)**

48” (121.9 cm)**;

48 1/8” (122.2 cm)***

43 1/2” (110.5 cm)

*Recommended, **Minimum, ***Maximum

13" (33.0 cm) max.

5

Non-combustible

Surface along back wall

recommended

Top of

finished

counter

10" (25.4
cm) min. to
combustible
side walls
above range
(both sides)

Standard Cutout

with Range Hoof

Cutout with Optional Downdraft Vent

(Top View)

10" (25.4 cm) mín.

to combustible side

walls above range

(both sides)

Note 2

Backsplash

3" (7.6 cm)

C

B

Non-combustible rear
wall (recommended)

3/8" (1.0 cm) min.
flat countertop
overhang

Suggested
location of
utilities

3

37 1/2"

(95.3 cm)

max.

18" (45.7cm)

4.5

Note 2

Grate
level

30" (76.2 cm)
max.

1

B

A

1.

Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood
specifications for minimum required clearances.

2.

Cabinet/countertop depth is at the customer's discretion, but cabinet face must not protrude beyond the rear
of the front panel. (See Product Dimensions,

Pg.

14

)

3.

Consult local codes for exact location requirements.

4.

Vertical from grate level to combustible surface.

5.

Does not apply to cabinets more than a horizontal distance of 10" (25.4 cm) from the range edge.

INSTALL_DOP36C86DLS_DA_DG68-01510A.indb 15