CUTOUT DIMENSIONS
Range Model
A
B
C
DOP36C86D**
42” (106.7 cm)*;
36” (91.4 cm)**
36” (91.4 cm)**;
36 1/8” (91.7 cm)***
33 1/2” (84.8 cm)
DOP48C86D**
54” (137.2 cm)*;
48” (121.9 cm)**
48” (121.9 cm)**;
48 1/8” (122.2 cm)***
43 1/2” (110.5 cm)
*Recommended, **Minimum, ***Maximum
13" (33.0 cm) max.
5
Non-combustible
Surface along back wall
recommended
Top of
finished
counter
10" (25.4
cm) min. to
combustible
side walls
above range
(both sides)
Standard Cutout
with Range Hoof
Cutout with Optional Downdraft Vent
(Top View)
10" (25.4 cm) mín.
to combustible side
walls above range
(both sides)
Note 2
Backsplash
3" (7.6 cm)
C
B
Non-combustible rear
wall (recommended)
3/8" (1.0 cm) min.
flat countertop
overhang
Suggested
location of
utilities
3
37 1/2"
(95.3 cm)
max.
18" (45.7cm)
4.5
Note 2
Grate
level
30" (76.2 cm)
max.
1
B
A
1.
Vertical from range grate level to combustible overhead surface; if installing an overhead hood, see hood
specifications for minimum required clearances.
2.
Cabinet/countertop depth is at the customer's discretion, but cabinet face must not protrude beyond the rear
of the front panel. (See Product Dimensions,
Pg.
)
3.
Consult local codes for exact location requirements.
4.
Vertical from grate level to combustible surface.
5.
Does not apply to cabinets more than a horizontal distance of 10" (25.4 cm) from the range edge.