beautypg.com

Installation instructions – Dacor Contemporary 36 Inch Freestanding Professional Gas Smart Range Installation Manual User Manual

Page 38

background image

English

38

Installation instructions

Installation instructions

Gas connection

WARNING

• Make sure the gas supply valve is off and that the power to the range is turned off at

the circuit breaker or fuse box prior to connecting the gas line.

• Do not overtighten the gas connections and fittings.
• Do not use Teflon tape or plumber’s putty on gas flex line connections.
• The maximum gas supply pressure to the regulator must never exceed 1/2 pound per

square inch (psi) or 3.5 kPa.

• The range and shut-off valve must be disconnected from the gas supply piping during

any pressure testing exceeding 1/2 psi (3.5 kPa).

• The range must be isolated from the gas supply piping by closing the shut-off valve

during any pressure testing at or below 1/2 psi (3.5 kPa).

• Check all gas lines for leaks as instructed to avoid a fire or explosion hazard. Do not

use a flame to check for leaks.

NOTE

The gas pressure regulator is pre-set at the factory for the type of gas intended for
use with the appliance. To verify that the appliance is compatible with the type of gas
available, check the range rating label (see page

6

for location). Consult your dealer if the

range is not compatible with the type of gas supplied.

Install_NX9900R_PRORANGE_DOP36M96_DA_DG68-01106C-02_EN+MES+CFR.indb 38

2019-08-13 6:30:53