Cabinet dimensions, Standard cutout with range hood, Installation requirements – Dacor Contemporary 36 Inch Freestanding Professional Gas Smart Range Installation Manual User Manual
Page 26: Consult local code for exact location requirements, Vertical from grate level to combustible surface

English
26
Installation requirements
Installation requirements
Cabinet dimensions
• All maximum and minimum dimensions and clearances shown in the diagrams below
must be maintained for safe operation.
• Verify that the range installation site is away from any type of draft.
• To reduce risk of fire and personal injury, cabinets should not be installed above the
range. If such cabinets are unavoidable, install a range hood that projects 5" beyond
the front of those cabinets.
CUTOUT DIMENSIONS
Range Model
A
B
DOP36M96*
42” (106.7 cm)*
36” (91.4 cm)**
36” (91.4 cm)**
36 1/8” (91.7 cm)***
* Recommended ** Minimum *** Maximum
Standard Cutout with Range Hood
A
B
13” (33.0 cm)
max.
5
Non-combustible
surface along back wall
recommended
Top of
finished
counter
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
Suggested
location of
utilities
3
Grate
level
Note 2
18” (45.7 cm)
4, 5
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
1
Vertical from range grate
level to combustible overhead
surface; if installing an
overhead vent hood, also
check hood specifications for
minimum required clearances.
2
Cabinet/countertop depth
is at discretion of customer
but cabinet face MUST NOT
protrude further than rear
of front panel, see product
dimensions.
3
Consult local code for exact
location requirements.
4
Vertical from grate level to
combustible surface.
5
This specification does not
apply for cabinets more than
a horizontal distance of 10”
(25.4 cm) from the edge of the
range.