Installation instructions

Convert to lp gas (optional)

All new gas ranges are shipped from the factory set up to use natural gas. This Dacor gas
range can be converted to use LP gas. Refer to page 78 in the User Manual to contact a
qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion kit.
The conversion to LP requires all burner orifices to be changed (5 surface burners and
2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All replaced
orifices must be left with the consumer, including the instructions and retrofit sizes and
orifice indication.

BURNER ORIFICE SIZES AND OUTPUT RATINGS

(LP Gas [Propane] 10 in WCP)

Burner Location

BTU Rate

Orifice Size [mm]

LF

16,500

In 0.46 / Out 0.78*2

LR

14,500

In 0.46 / Out 0.74*2

RF

16,500

In 0.46 / Out 0.78*2

RR

14,500

In 0.46 / Out 0.74*2

CF

14,500

1.12

CR

14,500

1.12

Broil

14,500

0.79*2

Bake

23,000

1.4