Installation Guide

2. Wall Construction

This Built-In Microwave Hood should be mounted against

and supported by a flat vertical wall. The wall must be flat

for proper installation. If the wall is not flat, use spacers to

fill in the gaps.
Wall construction should be a minimum of 2” x 4” wood

studding and

3

/

8

” or more thick drywall or plaster/lath.

The mounting surfaces must be capable of supporting a

weight of 110 pounds—the oven and contents—AND the

weight of all items that would normally be stored in the top

cabinet above the unit. The unit should be attached to a

minimum of one 2” x 4” wall stud.
To find the location of the studs, one of the following methods

may be used:
• Use a stud finder, a magnetic device which locates the

nails in the stud.

• Use a hammer to tap lightly across the mounting surface

to find a solid sound. This will indicate stud location.

The center of the stud can be located by probing the wall

with a small nail to find the edges of the stud and then

placing a mark halfway between the edges. The center of

any adjacent studs will normally be 16” or 24” to either

side of this mark.

2"x 4" Wood Studs

or Plaster/Lath

3/8" Dry Wall

16" or 24"

Figure 2

NOTE:

In the event that the unit will be unable to be

supported by any stud, it will be necessary to use special

care in the placement of the toggle bolts and top cabinet

screws. See Wall Template for details. The top cabinet

should be tested to ensure it is securely attached to the

wall. Place extra weight up to 110 pounds inside the top

cabinet to test the support.

3. ELECTRICAL

GROUNDING

INSTRUCTIONS

This appliance must be grounded. This oven is equipped

with a cord having a grounding wire with a grounding

plug. It must be plugged into a wall receptacle that is

properly installed and grounded in accordance with the

National Electrical Code and local codes and ordinances.

In the event of an electrical short circuit, grounding reduces

risk of electric shock by providing an escape wire for the

electric current.

WARNING

- Improper use of the grounding plug can result

in a risk of electric shock.
The Power Supply Cord and plug must be connected to a

separate 120 Volt AC, 60 Hz, 15 Amp, or more branch

circuit, single grounded receptacle.

Ground

Receptacle

Opening for

Power Cord

Figure 3

NOTE:

1. If you have any questions about the grounding or

electrical instructions, consult a qualified electrician or

serviceperson.

2. Neither Fulgor Milano nor the dealer can accept any

liability for damage to the oven or personal injury

resulting from failure to observe the correct electrical

connection procedures.

1.TINSKB287MRR0_FULGOR OTR_F4OTR30S1_Install.indd 3