Installation & Assembly

FIGURE 2: Ener-Radiant XL Overview Key

Burner Housing
Must always be
installed horizontally.

Tube and Reflector Hanger
Install immediately after first
coupling.

Turbulator Assembly
Enerco normally ships Ener-Radiant heaters with
turbulators assembled into appropriate tubes.

Tube and Reflector Hanger
Suspend system from these hangers.
Minimum two (2) required per tube.

Reflectors
Alternate overlap as shown
on overview. Length of
reflector and amount of
overlap is indicated.

10' 2=1/2"

ALUMINIZED

Heat Exchange Tubes
Supplied in 10 ft. lengths.

Tube Coupling Assembly
Coupling should be oriented with slide
bar on top, and all couplings should
“point” in the same direction.

Vent Adapter
Used to attach the heat exchanger
tubing to vent pipe.

Where Field Changes Occur
Turbulator Sections and Adapter are available in
sections and must be assembled before installation
(See Figure 7 for details). The number of sections
required is indicated.

Suspensions point
Use S-Hooks (See Figure 5) for suspension
details.

HANGER

HANGER

HANGER

HANGER

18”

18”

18”

18”

18”

18”

18”

18”

18”

18”

10’ 2-1/2”

10’ 2-1/2”

10’ 2-1/2”

10’ 2-1/2”

10’ 2-1/2”

2-1/2” OVERLAY TYP

ALUMINIZED

(4) Turbulator Sections
(1) Turbulator Adapter

(4) Turbulator Sections
(1) Turbulator Adapter

ALUMINIZED

ALUMINIZED

ALUMINIZED

FIGURE 2a: Ener-Radiant XL Model ERXL-60, ERXL-80S, Assembly Overview

20 ft. Exchanger length. 21 ft. - 4 in. Total Heater length. 4 Suspensin points indicated.

FIGURE 2b: Ener-Radiant XL Model ERXL-80, Assembly Overview

30 ft. Exchanger length. 31 ft. - 4 in. Total Heater length. 6 Suspension points as indicated