beautypg.com

Installation – Enviro WINDSOR 50-1578 User Manual

Page 7

background image

7

Figure 2: Windsor Dimensions.

27

1

/

8

"

(689mm)

25

3

/

4

"

(653mm)

25

7

/

8

"

(659mm)

15

3

/

8

"

(390mm)

14

1

/

4

"

(360mm)

24

1

/

8

"

(614mm)

Installation

D

IMENSIONS

& S

PECIFICATIONS

:

Table 1: Windsor Specifications.

Classification

Testing Standard

Description

Class I IP-20

EN14785:2006

Residential Wood Pellet Heater

Voltage

Current

Frequency

220 - 240 V

2.0 - 2.3 Amps

50 Hz

Maximum Power Requirement

Fuel type

Calorific value of Pellet used

525W (1793 BTU/hr)

wood pellets - 6mm (1⁄4”) dia.

≥ 5.10 kWh/kg (≥ 8000 BTU/lb)

Maximum Flue Gas Temperature

Mean Flue Gas Temperature

Mean Flue Gas Temperature (Reduced)

230°C (446°F)

180.5°C (357°F)

128.5°C (263°F)

Nominal Heat Output

CO emissions from Combustion

Energy Efficiency

6.9 KWh (23544 BTU)

0.035%

82.6%

Reduced Heat Output

CO emissions from Combustion (Reduced Output)

Energy Efficiency (Reduced Output)

2.3 KWh (7848 BTU)

0.052%

77.3%

CO

2

at Nominal Output

Nominal Fuel Consumption Rate

Unit with Full Hopper

8.16%

1.65 Kg/hr (3.64 lb/hr)*

~ 151kg (333lb)

CO

2

at Reduced Output

Fuel Consumption Rate (Reduced Output)

Hopper Capacity

4.142%

0.59 Kg/hr (1.30 lb/hr)*

~ 20kg (45lb)

*Note: Consumption will vary with the type of fuel used.