beautypg.com

Installation – Enviro WINDSOR 50-1578 User Manual

Page 20

background image

S

LIDER

/D

AMPER

S

ETTING

:

THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE

THE AIRFLOW THROUGH THE PELLET STOVE.

A Qualified Service Technician or Installer must set the Slider Damper.

If the unit has been placed in the HI / LOW mode,

the unit will be taken to a low or idle setting when

the thermostat is not calling for heat. When the

thermostat calls for heat, the unit will go to the

setting that is displayed on the control board Heat

Indicator. If the heat in the room becomes to great,

the high limit switch may turn the stove off and

the switch will have to be manually reset. To reset

the high limit switch, remove the right cabinet

side. The switch is found behind the control panel.

Avoid setting off the high limit switch.

Installation

T

HERMOSTAT

I

NSTALLATION

:

1. Install the wall thermostat (12 or 24 Volt rated) in a location that is not to close too the unit but will

effectively heat the desired area.

2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat.

Figure 21: Thermostat wire placement.

Figure 22: Slider / Damper

Note: Some parts have been removed in

order to see components more clearly.

Slider Damper Plate

Exhaust Channel

Exhaust Blower

The slider damper should

be set only on a hot stove

(operating for thirty (30)

minutes or more) by placing

a Magnahelic Pressure Gauge

in the firebox (test port is

located in the center of the

stove just below the door

opening). Set the slider

damper so that the pressure

reads 0.18” to 0.20” W.C.

(44.8 to 49.8 Pa). Some

fuels may require higher

or lower settings. The

pressure readings are taken

through a hole in the front

of the firebox under the door,

using a Magnehelic Gauge.

20