ENVISION RESIDENTIAL INSTALLATION MANUAL

Envision - Dual Capacity Wiring Schematic - 208-230/60/1

97P774-02 6/29/06

PB2

Auxiliary Electric Heat Power

208-230/60/1

Violet

Blu

With optional ' EA' Series
Auxiliary ElectricHeat
Typical schematic shown

2

3

HE1

TS1

HE2

TS2

HE3

TS3

HE4

TS4

P7

L4

L2

L2

NOTE 5

Pink

Yel

Blk

Gray

Pink

Yel

Blk

Gray

Gray

Blk

Yel

Pink

Gray

Pink

Blk

Yel

Pink

Yel

Blk

Gray

Pink

Yel

Blk

Gray

Grn

F2

P9

ER1

ER2

ER3

ER4

L1

L1

L3

NO

NO

NO

NO

Brn

Org

Brn

Or

5

4

Pink

Orange

White

Tan

Blue

Violet

Blue

Yellow

Black

Gray

Red

EA Series PCB

E-Series Logic Board - Physical Layout

1

1

2

3

P10

4

5

6

P2

1

G

G

4

3

2

1

P8

1

2

3

4

Thermistor

Light emitting diode - Green

Relay coil

Capacitor w/ bleed resistor

Switch - Condensate overflow

Switch - High pressure

Switch - Low pressure

Switch -Hot Water On/Off

Polarized connector

Factory Low voltage wiring
Factory Line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
DC Voltage PCB traces
Internal junction
Quick connect terminal

Wire nut

Field wire lug

Ground

Fuse

CC -
CO -
CR1 -
CR2-
CR3 -
CR4 -
F1 and F2 -
FP -
HE -
HP -

LP -
PB1, PB2 -
PS -
RV -
SW1 -
SW2 -
SW3 -
SW4 -
TS -

Compressor Contactor
Condensate overflow sensor
DHW pump relay

Loop pump relay

Fuses
Freeze protection sensor
Heater element
High pressure switch

Low pressure switch
Power blocks
Power strip
Reversing Valve coil
DIP package 12 position
DIP package 8 position
DIP package 5 position
Hot water pump enable switch
Thermal limit switch

Legend

Relay Contacts-
N.O., N.C.

G

T

1

3

2

P

L1

PSC Fan Speed Relay
PSC Fan Power Relay

ER1 to ER4 -

Aux heat stage relays

HWL -

Hot water limit sensor

1 2 3

1

P4

On

Off

SW1

24

0V

-

L2

24

0V

-

L1

Fu

se

d

L2

Fu

se

d

L2

Fu

se

d

L2

F1

F1

R
R

Microprocessor

E-Series Logic Board

CR2- Loop
Pump

N.O.

24

0V

-

L2

24

0V

-

L1

C
C

1

2
3
4
5
6
7
8

9

10
11
12
13
14
15
16

P6

1
2
3
4
5
6
7

8
9

10
11
12
13
14

P5

Fu

se

d

L2

Fu

se

d

L1

CR1- DHW

Pump

N.O.

CC

CC-GND

CCLO
CCHI

1

2

3

P3

2

3

4

5

6

7

8

9

10

11

12

1

On

Off

SW2

2

3

4

5

6

7

8

1

On

Off

SW3

2

3

4

5

P1

1

2

3

4

5

6

7

8

2

3

4

5

P2

6

7

1

R C Y1 Y2

G

O

W

L

Shut

Down

ACC

NO

ACC

NC

ACC
COM

C

C

SL1

IN

SL1

Out

SL2

IN

SL2

Out

L1

L2

Single Disconnect Power

208-230/60/1

Aux Elect Power

208-230/60/1

L1

L2

L1

L2

Unit Power

208-230/60/1

CSA installed units only

Local codes may require a single

source of power supply

Breaker box
furnished by

installer

Circuit Breakers

N.O.

CR4-

Com

N.O.

CR3-

Com

N.C.

SC -

Start Contactor

Start Relay

SR -

CS -

Compressor Solenoid

ECM2

Fan Motor

Grn

15

10

16

3

O

n/

O

ff

PW

M

R

PM

C

2

R

PM

g

rn

d

P12

P11

2

3

4

5

1

8

CA -

Comfort Alert

NOTES

97P774-02 8/1/08

1. Switch Blue and Red wires for 208V operation.
2. Connection of remote unit that does not have a loop pump for slave operation.
3. 24V Accessory relay (see SW2 -3 for description of operation).
4. The blk/wh and gray/wh wires are removed when Aux Heat is installed.
5. Buss lugs L1 and L2 can be removed and dual power wire sets connected directly to box lugs L1, L2, and L3, L4.
6. DHW pump only in models with hot water generation option.
7. Air Flow Configuration Example: SW1 configured for dip 1 as low, dip 3 as medium, and dip 5 as high speed ECM2 fan.
8. SW3-4 should be in the OFF position when using ECM motor and 17P501A01 electric heat board and should be ON when

using ECM2 with 17P514A01 electric heat board.

9. SW2-8 must be in the OFF position for pulsed “L” lockout signal and in the ON position for constant “L” lockout signal.
10. When optional electronic air-filter is installed, power for the electronic air-filter is provided by P2-2 and 24 VAC.
11. Comfort Alert fault output to Premier Control Board.
12. This switch allows the unit to down stage with the t-stat when off and finish with second stage when on. Finish on second

stage reduces stage changing in recip dual capacity compressors and should be ON for unzoned Dual Cap E Series or

Premier 2 Speed.

Y2

Y

L

R

C

DC

Sol

Data

Port

Comfort Alert Physical Layout

POWER

ALERT

TRIP