beautypg.com

Commissioning, Pressure testing – Electrolux 20604 G - 21604 User Manual

Page 24

background image

58

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting.

To do this, follow the procedure below.

1) Turn the gas tap to the MAX position and ignite.
2) Set the gas tap to the MIN flame position then turn the control knob from MIN to

MAX several times. If the flame is unstable or is extinguished follow the procedure

below.

Procedure:

1) Re-ignite the burner and set to

MIN.

2) Remove the control knob.
3) You can find two different

adjustment screw locations

according to the gas tap (see

diagram). The "b" type has the

adjustment screw located down the

centre of th egas tap control shaft.

The "c" type has the by pass screw

located to the side of the gas tap

itself.
To adjust, use a thin bladed

screwdriver and turn the adjustment screw until the flame is steady and does not

extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for

all burners.

Pressure Testing

1) Remove left hand pan support and front left burner cap and crown.
2) Fit manometer tube over the injector.
3) Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20mbar and must be between 17 mbar

and 25mbar.

4) Turn off the burner supplies.

a) Minimum adjustment screw

b) Tap

FO 1032

F

F

F