53

Electrical connections

Any electrical work required to install this hob should be carried out by a qualified

electrician or competent person, in accordance with the current regulations.
THIS HOB MUST BE EARTHED.

The manufacturer declines any liability should these safety measures not be observed.
This hob is designed to be connected to a 230-240V 50Hz AC electrical supply.
Before switching on, make sure the electricity supply voltage is the same as that indicated on the

hob rating plate. The rating plate is located on the bottom of the hob. A copy is attached on the

back cover of this book.
The hob is supplied with a 3 core flexible supply cord incorporating 13 amp plug fitted. In the

event of having to change the fuse, a 3amp ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in

accordance with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

1) Connect the green and yellow (earth)

wire to the terminal in the plug which

is marked with the letter 'E' or the

earth symbol

or coloured green

and yellow.

2) Connect the blue (neutral) wire to the

terminal in the plug which is marked

with the letter 'N' or coloured black.

3) Connect the brown (live) wire to the

terminal in the plug which is marked

with the letter 'L' or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp

must be secure over the outer sheath.

A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard.

Ensure that the cut off plug is disposed of safely.

FO 0390