English, Names of parts, Front panel – Tascam ML-32D Dante / Analog Converter User Manual
Page 7: 7names of parts
TASCAM ML-32D / ML-16D
7
Names of Parts
Front panel
ML−32D
ML−16D
1
POWER button and indicator
Press this button to turn the unit on and off.
2
STATUS indicator
The STATUS indicator shows the state of the unit by lighting
blue or red or staying unlit. “STATUS indicator lighting status
details” on page 7
3
SAMPLE RATE indicator
The three SAMPLE RATE indicators (44.1k, 48k and ×2) light
to show the sampling frequency status of the unit.
44.1kHz
48kHz
x2
44.1kHz
Lit
Unlit
Unlit
48kHz
Unlit
Lit
Unlit
88.2kHz
Lit
Unlit
Lit
96kHz
Unlit
Lit
Lit
4
OL indicators
These light when analog input signals overload.
5
IN SIG indicators
These light when sound is being input through the analog
inputs.
Input is judged to have occurred when the signal level ex-
ceeds −60 dBFS.
6
OUT SIG indicators
These light when sound is being output through the analog
outputs.
Output is judged to have occurred when the signal level ex-
ceeds −60 dBFS.
STATUS indicator lighting status details
STATUS indicator
Note
Ordinary operation
Lit blue
Malfunctioning
(Dante)
Rapidly flashing red
(four times per second)
The Dante module is malfunctioning.
Muted
Lit red
The indicator lights red when the clock is stabilizing after the unit starts up and when
the sampling frequency or other Dante setting has been changed, for example.
Dante network error
Flashing red
(twice per second)
The Dante network is not connected.
Dante redundancy
error
Blinking blue
(once per second)
Redundancy is set and the secondary is being used because the primary is unavail-
able.