TASCAM ML-32D / ML-16D

7

Names of Parts

Front panel

ML−32D

ML−16D

1

POWER button and indicator

Press this button to turn the unit on and off.

2

STATUS indicator

The STATUS indicator shows the state of the unit by lighting
blue or red or staying unlit. “STATUS indicator lighting status
details” on page 7

3

SAMPLE RATE indicator

The three SAMPLE RATE indicators (44.1k, 48k and ×2) light
to show the sampling frequency status of the unit.

44.1kHz

48kHz

x2

44.1kHz

Lit

Unlit

Unlit

48kHz

Unlit

Lit

Unlit

88.2kHz

Lit

Unlit

Lit

96kHz

Unlit

Lit

Lit

4

OL indicators

These light when analog input signals overload.

5

IN SIG indicators

These light when sound is being input through the analog
inputs.
Input is judged to have occurred when the signal level ex-
ceeds −60 dBFS.

6

OUT SIG indicators

These light when sound is being output through the analog
outputs.
Output is judged to have occurred when the signal level ex-
ceeds −60 dBFS.

STATUS indicator lighting status details

STATUS indicator

Note

Ordinary operation

Lit blue

Malfunctioning
(Dante)

Rapidly flashing red
(four times per second)

The Dante module is malfunctioning.

Muted

Lit red

The indicator lights red when the clock is stabilizing after the unit starts up and when
the sampling frequency or other Dante setting has been changed, for example.

Dante network error

Flashing red
(twice per second)

The Dante network is not connected.

Dante redundancy
error

Blinking blue
(once per second)

Redundancy is set and the secondary is being used because the primary is unavail-
able.