Get-function listing – VIEWSONIC ViewBoard IFP8662 86" 4K Interactive Display User Manual
Page 115

115
Get-Function Listing
The PC can interrogate the LFD for specific information. The Get-Function packet
format consists of 9 bytes which is similar to the Set-Function packet structure.
Note that the “Value” byte is always = 000.
Get-Function Description:
Length:
Total Byte of Message excluding “CR”.
TV/DS ID
Identification for each of TV/DS (01~98; default is 01).
Command Type
Identify command type,
“g” (0x67h) : Get Command
“r” (0x72h) : Valid command Reply
“-“ (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code.
Value[1~3]:
Three bytes ASCII that defines the value.
CR
0x0D
Get-Function Format
Send: (Command Type=“g”)
Name
Length
ID
Command Type Command
Value1 Value2 Value3 CR
Byte
Count 1 Byte
2
Byte
1 Byte
1 Byte
1 Byte 1 Byte 1 Byte
1
Byte
Bytes
order
1
2~3
4
5
6
7
8
9
Reply: (Command Type=“r” or “-”)
If the Command is valid, Command Type = “r”
Name
Length
ID
Command Type Command
Value1 Value2 Value3 CR
Byte
Count 1 Byte
2
Byte
1 Byte
1 Byte
1 Byte 1 Byte 1 Byte
1
Byte
Bytes
order
1
2~3
4
5
6
7
8
9
If the Command is NOT valid, Command Type = “-”
Name
Length
ID
Command Type
CR
Byte
Count
1 Byte 2 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5