JUMPER SETTINGS

Function

Model

Jumper Jumper Details

Mute-Receive

M-11, T-12, U-11,

J5

J6

U-12, U-13, U-14R

ON

ON

Responds to both Mute Bus #1 and Mute Bus #2
activation.

CUT

ON

Responds to Mute Bus #1 activation only

ON

CUT

Responds to Mute Bus #2 activation only

CUT

CUT

No mute function

B-11, L-11

D3

D4

ON

ON

Responds to both Mute bus #1 and Mute bus #2
activation.

CUT

ON

Responds to Mute Bus #1 activation only

ON

CUT

Responds to Mute Bus #2 activation only

CUT

CUT

No muting

M-11S Mute Response Mode

M-11

J3

J4

(Normally-On or Normally-Off)

ON

ON

No output signal - cut J3 or J4.

CUT

ON

Normally "OFF" turns "ON" during mute bus activation

ON

CUT

Normally "ON" turns "OFF" during mute bus activation

CUT

CUT

No muting function.

Mute-Send

S-20S

SJP2

Enables Mute Send (VOX)

M-41, U-43

J5

J6

ON

ON

Activates both Mute Bus #1 and Mute Bus #2

CUT

ON

Activates only Mute Bus #1

ON

CUT

Activates only Mute Bus #2

CUT

CUT

No mute activation.

B-41, L-41

D3

D4

ON

ON

Activates both Mute Bus #1 and Mute Bus #2

CUT

ON

Activates only Mute Bus #1

ON

CUT

Activates only Mute Bus #2

CUT

CUT

No mute activation.

Phantom Power

M-01, M-11, M-21,

J1

M-41, M-51, M-61

CUT

Disables phantom power.

Master Compressor

U-61

J2

CUT

Configures module as a Master Compressor

(see page 23).

Remote Master Volume

U-21

CUT

Configures module as a Remote Master Volume control

(see page 21).

Input Impedance Conversion

L-01, L-11, L-41

R1

(600

to 10 k

)

CUT

Changes input impedance from 600

to 10 k

allowing maximum voltage transfer (see page 16).

Hysteresis

ML-11T

SJP101

CUT

Disables Mute Send hysteresis

Mute Send (VOX)

SJP102

ON

Enables VOX function

OFF

Disables VOX function

Mute Bus #1

SJP103

Receive

Responds to Mute Bus #1 activation only

Send

Activates only Mute Bus #1

N/A

Disconnects from Mute Bus #1

Mute Bus #2

SJP104

Receive

Responds to Mute Bus #2 activation only

Send

Activates only Mute Bus #2

N/A

Disconnects from Mute Bus #2

Note:

1. In many applications, NO jumper changes are required. Mute-Receive and Mute-Send modules connect to both Mute Bus #1 and Mute Bus #2

by default.

2. Configure the M-11S Mute Response Mode before use - it will not pass signal out-of-the-box.