TOA Electronics ZM-9012 Assignable Volume Controller User Manual
TOA Electronics Audio accessories

ZM REMOTE CONTROLLER CONNECTION
INSTRUCTIONS (Supplementary)
When using the ZM Remote controller (ZM-9011, ZM-9012, ZM-9013, or ZM-9014 Remote
Control Panel), be sure to read the separate instruction manual in conjunction with this
supplementary manual.
1. CONNECTION
(Example of LINK A connections)
M-864D
Side view of the ZM
Remote controller
※
Notes
• Use the shielded Category 5 twisted pair LAN cable for connections between the ZM Remote
controller and the M-864D Digital Stereo Mixer (※ mark as shown above).
• Connect all cables as shown in the wiring diagram below.
Shield
Shielded wire
ZM 9011/9012/9013/9014
M-864D
Terminal
Cable (Color)
D+
White/Orange
D−
Orange
White/ Green
Green
Shield
24V+
White/Blue
White/Brown
24V–
Blue
Brown
URL: http://www.toa.jp/
133-05-00001-00
2. CABLE DISTANCE
Note
When 2 or more ZM Remote controllers are connected in a star topology, keep each cable length
within 10 m (33 ft) from the M-864D to a branch point.
(When connecting 16 ZM Remote controllers)
LINK A
LINK B
ZM Remote
controller (1)
(8)
Connection terminal
Connection terminal
(9)
(16)
Allowable total cable length
of wiring is 800 m (870 yd).
M-864D
Max. 10 m (33 ft) to
a branch point