B-11
B-21
B-21S
Balanced Line Input with Remote Volume Control
B-11S
Balanced Line Input with Mute-Receive
•
For Balanced Or Unbalanced Line Level Sources
such
as mixer outputs, signal processors and wireless
microphone receivers.
•
Transformer Isolation (10 k
Ω
)
minimizes ground loop
problems when connecting remote equipment (greater than
15 feet).
•
Remote Volume Control
by connecting an external 10
k
Ω
, linear-taper potentiometer to screw terminals #4 and
#5.
Note:
Control line resistance greater than 200
Ω
will
prevent full attenuation (200
Ω
= 3821 ft. of #24 AWG
wire).
•
Tip!
You can also connect a switch between screw
terminals #4 and #5 for remote on/off operation. Closing
the switch turns the module OFF, opening the switch turns
the module ON.
•
Connector:
screw terminal (B-21S).
Faceplate Controls
Gain, terminals for 10 kohm linear-taper pot.
Input Impedance
10 kohms, balanced transformer-isolated
Sensitivity
-16 ~ +14 dBu
Gain
-32 ~ -2 dB
CONNECTOR DIAGRAM
SPECIFICATIONS
BLOCK DIAGRAM
•
For Balanced Or Unbalanced Line Level Sources
such
as mixer outputs, signal processors and wireless
microphone receivers.
•
Transformer Isolation
minimizes ground loop problems
when connecting remote equipment (greater than 15 feet).
•
Responds To Mute Bus Activation
, via Mute SEND
module or switch-closure.
•
Responds To Both Mute Bus # 1 And Mute Bus # 2 By
Default
(cut diode(s) to disconnect individual mute bus).
•
Connector:
removable terminal block (B-11S).
PCB Controls
Mute bus selection
Input Impedance
10 kohms, balanced transformer-isolated
Sensitivity
-16 dBu
Gain
-1 dB
CONNECTOR DIAGRAM
SPECIFICATIONS
BLOCK DIAGRAM
LINE INPUT MODULES: BALANCED
PAGE 14
B-11S (old style)
B-11S (new style)
B-11S (Balanced/Unbalanced*) (old style)
B-21S
B-21S (Balanced/Unbalanced*)
*
For unbalanced sources, use a shielded, twisted pair and
connect the output to Hot and Common (inner conductors).
Connect the shield to Earth at the module and leave
unterminated (floating) at the source.
*
For unbalanced sources, use a shielded, twisted pair and
connect the output to Hot and Common (inner conductors).
Connect the shield to Earth at the module and leave
unterminated (floating) at the source.
B-11S (Balanced/Unbalanced*) (new style)