beautypg.com

L-11s line matching input with mute-receive, L-41s line matching input with mute-send – TOA Electronics U-13R - Unbalanced Line Input Module with High/Low Cut Filters and Mute-Receive for 900 Series (Dual RCA) User Manual

Page 16

background image

For Applications Requiring 600 Ohm Line Matching.

Transformer Isolation (600

)

minimizes ground loop

problems when connecting remote equipment (greater than
15 feet).

Signal At Input Terminals Activates Both Mute Bus #
1 and Mute Bus # 2 Buses by Default

(cut diode(s) to

disconnect individual mute bus).

Connector:

removable terminal block (L-41S).

Faceplate Controls

Mute send sensitivity

PCB Controls

Mute bus selection

Input Impedance

600 ohms, balanced transformer-isolated

Sensitivity

-16 dBu, min. -34 dBu to activate mute
function

Gain

-2 dB

L-41S (old style)

L-41S (Balanced/Unbalanced*) (old style)

SPECIFICATIONS

BLOCK DIAGRAM

L-41S (new style)

L-11S

Line Matching Input with Mute-Receive

For Applications Requiring 600 Ohm Line Matching.

Transformer Isolation (600

)

minimizes ground loop

problems when connecting remote equipment (greater than
15 feet).

Responds To Mute Bus Activation

, via Mute SEND

module or switch-closure.

Responds To Both Mute Bus # 1 And Mute Bus # 2 By
Default

(cut diode(s) to disconnect individual mute bus)

Connector:

removable terminal block (L-11S).

PCB Controls

Mute bus selection

Input Impedance

600 ohms, balanced transformer-isolated

Sensitivity

-16 dBu

Gain

-1 dB

CONNECTOR DIAGRAM

BLOCK DIAGRAM

SPECIFICATIONS

L-11S (old style)

L-11S (new style)

L-11S (Balanced/Unbalanced*) (old style)

L-41S

Line Matching Input with Mute-Send

LINE INPUT MODULES: LINE MATCHING

PAGE 17

L-11

L-41

CONNECTOR DIAGRAM

*

For unbalanced sources, use a shielded, twisted pair and

connect the output to Hot and Common (inner conductors).
Connect the shield to Earth at the module and leave
unterminated (floating) at the source.

*

For unbalanced sources, use a shielded, twisted pair and

connect the output to Hot and Common (inner conductors).
Connect the shield to Earth at the module and leave
unterminated (floating) at the source.

L-11S (Balanced/Unbalanced*) (new style)

L-41S (Balanced/Unbalanced*) (new style)