Supply talk battery power – Triplett CTX690 Tone and Probe Kit User Manual
Page 7

8 www.triplett.com
UM-CTX690
Before connecting to an unknown cable/wire to the Net
Toner in “Cont” mode, use the OFF/LINE mode to check and
ensure that cable/wire are not powered. Connecting the live
powered cable in “Cont” mode may damage the Net Toner
or cause erroneous results.
1.
With the left slide switch in “Cont/Talk” position
and right slide switch in “Cont” position.
2.
Connect the red and black clips to both ends of the
cable/wire that you want to test.
3)
The “Cont” LED indicator will light green. Bright green
indicates a low resistance path. Dim green indicates a
high resistance path. No Light, indicates an open
circuit.
4)
When a short circuit is detected, the “Cont” LED indicator will
light green.
5)
Move th
e left slide switch to “OFF/LINE” position when
finished to avoid draining battery of clips touch during
storage.
Supply Talk Battery Power
The talk battery mode should not be used with voltage present.