Fj200 strobe: warnings – Westcott FJ200 Strobe User Manual
Page 8
![background image](https://www.manualsdir.com/files/869779/content/doc008.png)
FJ200 Strobe: Warnings
Caution
●
IMPORTANT:
During operation, the flash tube, LED modeling lamp, and select components of
the FJ200 strobe temperatures will increase. Please use caution while using to avoid serious
burns or injuries.
●
Use only with the Westcott FJ200 Lithium Polymer Battery and/or AC Power Adapter and Cord.
●
Do not touch the flash tube, LED modeling lamp, metal reflector, metal snoot, and other metal
components and accessories after immediate use to avoid potential injury.
●
Never leave unattended around children and/or pets.
●
Keep away from fire, water, and moisture.
●
Do not submerge in water.
●
Avoid drastic temperature changes before, during, or after use.
●
Avoid direct skin contact with the flash tube and LED modeling lamp when replacing the flash
tube.
●
Always remove the FJ200 Lithium Polymer Battery from the FJ200 Strobe during travel/storage
to avoid accidental operation which could lead to overheating or permanent damage.
●
Do not overtighten the tilter bracket tension knob.
●
Ensure the FJ200 is securely mounted before use.
●
Only use FJ200 compatible modifiers and accessories and ensure they are securely attached to
the FJ200 Strobe before use.
●
Do not attempt to modify any Westcott products. Contact Westcott for assistance.
●
The operating temperature range is 14-104°F (-10-40°C).
Dual-Stage Heat Protection System
The FJ200 is equipped with a self-monitoring system ensuring safe operation during continued
full-power use during a short timeframe. The monitoring system provides a staged automatic shutoff
scenario;
●
Stage 1: Once the strobe reaches an internal operating temperature of 131°F (55°C) the screen will
display a red [
Bulb Icon
] and the recycle time will increase to 2 seconds in efforts to cool the unit
while allowing for further operation.
●
Stage 2: Once the strobe reaches an internal operating temperature of 167°F (75°C) the screen
will display a red
[OH]
icon and the unit will be inoperable for an estimated 10 minutes until an
adequate internal temperature has been reached to continue operation.
●
Once the unit has cooled, the [
OH]
will disappear from the screen and it will then be safe to
continue operation.
7