Fj200 strobe: mounting, Mounting to a light stand, Fj200 strobe: attaching & removing modifiers – Westcott FJ200 Strobe User Manual
Page 11: Removing the fj200 metal reflector & modifiers
![background image](https://www.manualsdir.com/files/869779/content/doc011.png)
1. Ensure the FJ200 strobe is
OFF
.
2. Remove the battery from FJ200.
3. Insert the 2-pin power cord in the FJ200 AC Adapter.
4. Align the metal contacts on the bottom of the AC Adapter to the pins inside the battery
compartment and gently press the AC Adapter into the battery compartment until it clicks into
place.
5. Plug the 2-prong connector into a standard wall outlet. (NOTE: Ensure that all electrical
components are compatible with the country being used.)
6. Turn the strobe
ON
by pressing and holding the
Power | Test
button until the start-up screen
appears. Release the
Power | Test
button.
FJ200 Strobe: Mounting
Mounting to a Light Stand
1. Attach the tilter bracket to the FJ200 by attaching the ¼”-20 thread attached to the tilter
bracket’s locking dial located on the tilter bracket to the bottom of the FJ200. (NOTE: The curved
side of the tilter bracket platform equipped with the ¼”-20 should face forwards.)
2. Rotate the tilter bracket’s silver locking dial clockwise until it’s securely affixed to the base of the
FJ200. (NOTE: Do not overtighten.)
3. Rotate the tilter bracket’s tension knob counterclockwise until the light stand receptacle is
perpendicular to the strobe body. Retighten by turning the knob clockwise.
4. Loosen the tension knob located lower on the tilter bracket.
5. Insert the light stand spigot into the FJ200’s 5/8"-16 mm tilter bracket receptacle.
6. Tighten the tension knob to secure the strobe to the light stand. (NOTE: Do not overtighten.)
FJ200 Strobe: Attaching & Removing Modifiers
Connecting the FJ200 Metal Reflector & Compatible Modifiers
1. Remove the FJ200’s Flash Tube Cover by sliding the adapter release towards the product logo,
rotate the flash tube cover counterclockwise, and pull away from the FJ200.
2. Grasp the FJ200 Metal Reflector (or compatible FJ200 modifier) and align its four square
mounting blocks with the openings located on the face of the strobe.
3. Insert the reflector or modifier and rotate clockwise until it locks into place.
Removing the FJ200 Metal Reflector & Modifiers
1. Ensure the strobe is turned
OFF
and has cooled for a minimum of five minutes before
proceeding.
2. With caution grasp the FJ200 Reflector or modifier.
3. Slide the strobe’s adapter release away from the modifier.
10