Starting the data analyzer, Stopping the data analyzer, Returning to the main menu – ProSoft Technology MVI46-GSC User Manual
Page 34

MVI46-GSC ♦ SLC Platform
Diagnostics and Troubleshooting
Generic Serial Communication Module
Page 34 of 78
ProSoft Technology, Inc.
December 5, 2007
Starting the Data Analyzer
Press [B] to start the data analyzer. After the key is pressed, all data transmitted
and received on the currently selected port will be displayed. An example display
is shown below:
The Data Analyzer displays the following special characters:
Character Definition
[ ]
Data enclosed in these characters represent data received on the port.
< >
Data enclosed in these characters represent data transmitted on the port.
These characters are inserted when the RTS line is driven high on the port.
These characters are inserted when the RTS line is dropped low on the port.
These characters are displayed when the CTS line is recognized high.
_TT_
These characters are displayed when the timing mark interval has been reached.
This parameter is user defined.
Stopping the Data Analyzer
Press [S] to stop the data analyzer. Use this option to freeze the display so the
data can be analyzed. To restart the analyzer, press [B].
Important:
When in analyzer mode, program execution will slow down. Only use this
tool during a troubleshooting session. Before disconnecting from the Config/Debug
port, please press [S] to stop the data analyzer, and then press [M] to return to the
main menu. This action will allow the module to resume its normal high speed
operating mode.
Returning to the Main Menu
Press [M] to return to the Main Menu.