PLANET MC-1600MR User Manual
Page 25
![background image](https://www.manualsdir.com/files/865427/content/doc025.png)
- 25 -
4.4.3.2 Set redundant [n] disable/enable
This command allows disable or enable per redundant group of Web Smart Media Converter Chassis, the correct usage is
shown as below:
Set redundant[n]disable/enable: n=1-8
, to disable or enable per redundant group of Web Smart Media Con-
verter Chassis, the screen in
Figure 4-15
appears.
Figure 4-15
Set redundant [n] disable / enable command screen
The redundant backup setting function already divides 8 redundant groups and each group includes 2 ports, the ports with
an odd number will be “Master”. Vice versa, the ports with even number will be Slave”.
Group
Master
Slave
1
1
2
2
3
4
3
5
6
4
7
8
5
9
10
6
11
12
7
13
14
8
15
16
Once enable the redundant backup setting function, only the Master fiber interface will work as a major fiber connection
and the Slave fiber interface as a backup fiber connection. When the system detects Master fiber interface disconnects
then the slave fiber interface will active as major fiber connection to avoid network downtime.
When the system detect the Master fiber interface of get recovery, then the Slave Fiber interface will disconnect auto-
matically and become a backup fiber connection again.
#
Notice:
LLCF must active on both Master and Slave devices. If not, then the redundant backup setting function will not
work.