beautypg.com

Pip (picture-in-picture) mode, Title mode, Dissolve mode – Extron Electronics RCP 2000 with ISS 506 User Manual

Page 16: Pip (picture-in-picture) mode -10 title mode -10, Dissolve mode -11, Operation, cont’d

background image

RCP 2000 with ISS 506 Support • Operation

Operation, cont’d

3-10

RCP 2000 with ISS 506 Support • Operation

3-11

To enter wipe mode,
1

.

Press and hold the Wipe button.

2

.

While holding down the Wipe button,

repeatedly press the Dissolve button until

“Wipe” is displayed on the LCD screen

(see the example at right).

3

.

If necessary, select a preview input.

4

.

Select a wipe transition sub-effect and duration. (See

“Selecting a wipe sub-effect,” later in this chapter.)

PIP (picture-in-picture) mode

In PIP mode, the preview input is displayed in a small window

within the program image. You can select from 25 transition

sub-effects (including dissolve, standard, curtain, square, and

plus) to use when the PIP window is opening and closing.
To enter PIP mode,
1

.

Press and hold the Wipe button.

2

.

While holding down the Wipe button,

repeatedly press the Dissolve button until

“Pip” is displayed on the LCD screen (see

the example at right).

3

.

Select a PIP transition sub-effect and its duration. (See

“Selecting a PIP sub-effect,” later in this chapter.)

4

.

To execute a preview/program switch in PIP mode, press

the Take button.

N

While the PIP window is displayed, the Take button

continues to blink, and the Picture Controls buttons, the

input buttons, the Wipe and Dissolve buttons, and all

Adjust knobs are disabled.

To access these controls, press Take or Cut, or slide the

T-bar all the way up or down. The Take button stops

blinking when the controls are available. The RCP

remains in PIP mode; to execute another switch using

the same PIP sub-effect, press Take or move the T-bar

again.

Title mode

In title mode, the preview image is superimposed over the

program image. You can select a brightness level (0 through

255), which indicates the intensity level at and above which the

preview image becomes visible. Any parts of the preview image

that are below the set level of intensity become transparent, so

that the program image shows through them on the display.

To enter title mode,
1

.

Press and hold the Wipe button.

2

.

While holding down the Wipe button,

repeatedly press the Dissolve button until

“Title” is displayed on the LCD screen (see

the example at right).

3

. Rotate the Adjust knob while the Wipe button is lit to select

the intensity level of the preview image that will become

transparent in Title mode. If the Wipe button is not lit,

press and release it.

N

You cannot apply any transition effects to the preview

input when the RCP is in Title mode. The preview

image is always displayed or removed with a cut.

4

.

If necessary, select a preview input.

5

.

To execute a preview/program switch with the title effect,

press the Take button.

N

While the title is displayed, the Take button continues

to blink, and the Picture Controls buttons, the input

buttons, the Wipe and Dissolve buttons, and all Adjust

knobs are disabled. To access these controls, press Take

again or press Cut. The Take button stops blinking

when the controls are available. The RCP remains in

Title mode; to execute another switch with the title effect,

press Take again.

N

The T-bar cannot be used when the RCP is in Title mode.

Dissolve mode

In dissolve mode, the program image fades out while the

preview image fades in. This is the only transition effect

available for this mode. (Dissolve mode is accessed directly by

pressing the Dissolve button; it is not on the Mode menu.)

N

Dissolve mode is full-screen only. To apply a dissolve

effect to the preview window in PIP mode, you must

select the PIP dissolve sub-effect (#01). See “Transition

Sub-effects,” later in this chapter.

To enter dissolve mode,
1

.

While the default cycle is running, press the Dissolve

button, which lights.

2

.

While the Dissolve button is lit, rotate the

Adjust knob to select the duration of the

dissolve effect (0.0 to 0.5 seconds) on the

LCD screen. If the Dissolve button is not lit, press and

release it.

Title

Lvl 150

Dissolve

0.5 Sec

Pip #03

0.5 Sec

Wipe #03

0.5 Sec

This manual is related to the following products: