Table 1, J1b1 port 0 port 7 – Avago Technologies MegaRAID SAS 9280-24i4e User Manual
Page 6

Page 6
LSI Corporation Confidential
|
May 2010
MegaRAID SAS 9280-24i4e RAID Controller Quick Installation Guide
Controller Installation
Table 1:
Jumpers and Connectors
Jumper/
Connector
Type
Description
J1A2
Universal Asynchronous
Receiver/Transmitter (UART) for the
Expander
4-pin connector
Reserved for LSI use.
J1B1
LED Locate and Fault Indication
header
Ports 0-3
Ports 4-7
2x8-pin connector
Connects to an LED that indicates whether a drive is in a fault condition. There is one LED
per port. When lit, each LED indicates the corresponding drive has failed or is in the
unconfigured-bad state.
The LEDs function in a direct-attach configuration (there are no SAS expanders). Direct
attach is defined as a maximum of one drive connected directly to each port.
NOTE: This header is used for RAID controllers with internal SAS ports only.
J1B2
x4 SAS Ports 24-27 external
connector
SFF-8088 x4 external mini SAS connector
Connects the controller by cable to a SAS/SATA backplane or an expander.
J1B3
Advanced Software Hardware Key
header
2-pin header
Enables support for selected advanced features, such as recovery, CacheCade, FastPath,
and SafeStore disk encryption.
J1C1
IPMI-style I
2
C connector
3-pin connector
Supports SES (SCSI enclosure services) over I
2
C through an internal I
2
C backplane cable
J1L1
Remote Battery Backup connector
(on the backside of the controller)
20-pin connector
Connects the LSIiBBU07 intelligent Battery Backup Unit or the LSIiBBU08 intelligent Battery
Backup Unit remotely to the RAID controller.
J2B1
x4 SAS Ports 0-3 internal connector
SFF-8087 x4 internal mini SAS connector
Connects the controller by cable to SAS drives or SATA 2 drives.
J2B2
x4 SAS Ports 4-7 internal connector
SFF-8087 x4 internal mini SAS connector
Connects the controller by cable to SAS drives or SATA 2 drives.
J2D1
Standard edge card connector
The RAID controller interfaces with the host system though a standard edge card.
This interface provides power to the board and an I
2
C interface connected to the I
2
C bus
for IPMI.
J3B1
x4 SAS Ports 8-11 internal connector SFF-8087 x4 internal mini SAS connector
Connects the controller by cable to SAS drives or SATA 2 drives.
J1B1
PORT 0
PORT 7
+ve
-ve
a
k