Control panel

Cleaning cycle time and duration is controlled from the control panel or

by PLC. From the control panel cycle time can be set to between 1–45

minutes, cleaning duration from 1–10 seconds. Timings are determined

by contamination levels.

Fluid flow configuration

A unique two chamber flow configuration ensures that maximum

filtration efficiency is achieved. Fluid is slowed in the Automag and

evenly distributed around the magnetic cores.

Magnetic cores

The magnetic cores are made using ‘rare earth’ neodymium iron boron

– currently the strongest permanent magnet material available. When

configured with pole concentrators, high-intensity magnetic fields

are generated which are capable of attracting even sub-micron sized

particles.

Each core is housed inside a stainless steel sleeve. The cores are held

together in a moveable ‘shuttle’ unit. Cleaning is triggered by a small

amount of compressed air moving the shuttle up out of the these

sleeves. The contamination, which has been held to the surface of the

sleeve by the magnetic field, is then released, allowing it to be purged

from the unit.

Purging

The purge valve is automatically opened as part of the cleaning

process. This redirects the fluid into a contamination collection tank.

A fixed amount of fluid is allowed through the Automag, purging the

contamination into this tank where it can be recycled and reclaimed.

Automag self-purging magnetic filter