beautypg.com

KEPCO RAX 50W User Manual

Page 2

background image

2

228-1225 REV 2

092200

KEPCO, INC. !"! 131-38 SANFORD AVENUE !" FLUSHING, NY. 11352 U.S.A.!" TEL (718) 461-7000!"! FAX (718) 767-1102!!

http://www.kepcopower.com "! email: [email protected]

BROWNOUT VOLTAGE:

115V a-c input selection, 80V a-c min. (82V a-c min. for model RAX 28-1.8K)
230V a-c input selection, 160V a-c min. (164V a-c min. for model RAX 28-1.8K)
320V d-c input selection, 220V d-c min. (Jumper in 230V a-c position)

INPUT CURRENT: (maximum load at 50°C with nominal output voltage):

INPUT PROTECTION AND SOFT START: A triac soft start circuit reduces start-up surge. Units are protected against shorts
by an input fuse. Fuse value 3.15A.

INPUT SURGE: At 25°C from cold start:

NOTE: There are two input surges at turn-on:

EFFICIENCY: 75% typical

STABILIZATION:

TRANSIENT RECOVERY: A step load change from 50% to 100% of rated load in 50 microseconds or more, produces no
more than 4% output voltage excursion. Recovery to 1% of the original voltage is less than 1 millisecond.

OUTPUT HOLDING TIME: Output is maintained for 20 milliseconds minimum upon input interruption (30 milliseconds typi-
cal) with nominal input voltage and output load at 50°C current rating.

OVERVOLTAGE PROTECTION: Fixed, factory set. See Table 1. The overvoltage circuit is reset by interrupting input for
approximately 15 seconds.

OPERATING TEMPERATURE: 0 -71°C. See the derating graph, Figure 1.

STORAGE TEMPERATURE: -20°C to + 75°C.

HUMIDITY: 20% to 95% relative humidity, noncondensing

ALTITUDE:

Operating: 10,000 feet (3048.0m)
Nonoperating: 35,000 feet (10,668m)

ISOLATION: (at 25°C ambient, 65% relative humidity):

Between input and output terminals, 3.75 KV a-c for 1 minute (with Y-capacitors removed).
Between input and output or chassis, 2000V a-c for 1 minute.
Between output terminals and chassis, 500V a-c for 1 minute.

INSULATION RESISTANCE: Between output and chassis, 100 megohms minimum (500V d-c)

LEAKAGE CURRENT:

0.5mA max at 120V a-c (U.L. Method)
0.75mA max at 240V d-c (U.L./VDE Method)

VIBRATION: Three Axes:

5-10 Hz., 10 mm amplitude
10-55 Hz., 2g

INPUT SOURCE

NOMINAL INPUT VOLTAGE

MINIMUM INPUT VOLTAGE

120 V a-c input selection

1.2A typ. - 1.6A max.

1.3A typ. - 1.8A max.

220-240V a-c input selection

0.6A typ. - 0.8A max.

0.7A typ. - 0.9A max.

d-c input selection

0.4A max. (320V input)

0.6A max. (240V input)

INPUT SOURCE

FIRST SURGE (5ms max.)

SECOND SURGE (3ms max.)

120 V a-c input selection

17A max.

5A typ.

220-240V a-c input selection

34A max.

3A typ.

320V d-c input selection

34A max.

3A typ.

CHARACTERISTIC

TYPICAL

MAXIMUM

Source Effect (min - max)

0.8%

1.5%

Load Effect, measured at sensing terminals (10% - 100% load change)

0.8%

1.5%

Temperature effect (0 to 71°C)

1.0%

2.0%

Combined effect (envelope)

2.0%

4.0%

Drift (8 hr. at 25°C)

0.1%

0.5%