beautypg.com

KEPCO FAW 100W Series User Manual

Page 2

background image

2

228-1158

080502

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

HOLD-UP TIME:

20 ms. typ. (120V a-c), 15 ms. min (100V a-c).

DIELECTRIC STRENGTH:

Between input and output: 2KV a-c for one minute.

Between input and output with Y-capacitor removed: 3.0KV a-c for one minute.

Between input and case (ground): 2.0KV a-c for one minute.

INSULATION RESISTANCE:

Between input and ground, output and ground, input and output;

100 Megohms min. (500V d-c).

LEAKAGE CURRENT

(UL method, 120V a-c, 50-60Hz, single terminal connection): 0.5 mA maximum.

(VDE method, 240V a-c, two terminal connection): 0.75 mA maximum.

SAFETY:

UL 1950 recognized (ambient temperature 40° C maximum); CSA E.B. 1402C Level 3 Certified (FAW 48-2K Level 1 Certified);

IEC 950 Approved by TÜV Rheinland (based on EN 60950/09.87, ambient temperature 50° C max.) - cover removed.

(+) SENSE, (–) SENSE:

See Figure 3. These terminals are provided to compensate for voltage drops in the load connecting wires. The

Sense terminals must be connected to their respective (+) and (–) output terminals, either at the load or at the Power Supply output termi-

nals. The connection ensures the most accurate error tracking. Error compensation in the connecting wires is up to 0.25 Volts for the FAW

5-20K model, and up to 0.4 Volts for all other models.

“POWER OK” SIGNAL OUTPUT:

The unit supplies a “POWER OK” logic 1 signal at CP51 (see Figure 2 and Figure 4, View “A”).

CONNECTOR TYPES:

Refer to the Mechanical Outline Drawing. The mating connector for CP51 is a Panduit, P/N CT10F22-2: Cover,

P/N TC100F-2.

CONNECTOR KIT:

Kepco furnishes an optional connector kit with the specified connector listed above. The kit may be ordered under

Kepco Model Kit P/N 518-0029. The connector is provided with 1 meter length leads for trimming to desired lengths.

EMI:

Designed to meet FCC Class B (100-120V a-c) and VDE 0871 Class B (220-240V a-c).

VIBRATION:

(non-operating, one hour on each one of the three axes):

5-10 Hz, 10 mm amplitude.

10-55 Hz, 2g acceleration.

SHOCK:

(non-operating, one-half sinusoidal pulse, three shocks to each axis):

Acceleration: 20g

Duration: 11ms +5ms

OPERATING TEMPERATURE:

0 - 71° C (see Figure 1).

STORAGE TEMPERATURE:

–40

o

C to +75

o

C.

OPERATING AND STORAGE RELATIVE HUMIDITY:

up to 95% (wet bulb temp. <35

o

C non-condensing).

MOUNTING SCREW:

No. 4-40 UNC Thread (see Figure 4)

MAXIMUM SCREW PENETRATION:

0.197 in. (5mm) max.

WEIGHT:

2.20 lbs. (1.0Kg max.), 3.31 lbs. (1.5 Kg max. with cover).

DIMENSIONS:

3.74 in. (95mm) H x 1.38 in. (35mm) W x 7.87 in. (200 mm) L

CASE DIMENSIONS:

3.74 in. (95mm) H x 1.50 in. (38mm) W x 7.87 in. (200 mm) L

FRAME MATERIAL:

Aluminum

FUSE:

Quick acting 5.0A, 250V; (5.2 x 20mm), San-O P/N EQ5.0A; Kepco P/N 541-0112.

WARRANTY:

1 year.