Page 24

– 21 –
(2)
Check if the surge absorber is burnt.
Check the resistance of surge absorber.
(3)
Measure the resistance of the diode.
8-5 CONDENSER
■ If an instrument (QC-meter or C-meter) for mea-
suring capacity of condenser is available, check
the capacity of condenser.
■ If such an instrument is unavailable, the condenser can be checked by replacing with a new one. If the
generator performs good with new condenser, the cause of trouble is defect in original condenser.
Normal resistance is
∞ Ω.
NORMAL CAPACITY OF CONDENSER
MODEL
RGD3300H
RGD5000H
60 Hz
60 Hz
CONDENSER
20 µF
30 µF
20 µF
30 µF
[Continuity exists.]
POLARITY OF
CIRCUIT TESTER
POLARITY OF
CIRCUIT TESTER
CONDENSER
1
2