6-5
Troubleshooting
Part of the image is periodically faint or
blurred.
Run [MC] and decrease the adjustment value. Decrease the adjustment
value 1 level at a time from the current value. If there is no improvement
after the value is decreased by 1 level, decrease by 1 level again. If there
is still no improvement, return the setting to the original value.
For details, refer to MC (Main charger output setting) on page 4-89.
Irregular horizontal lines appear in the
image.
Run [MC] and decrease the adjustment value. Decrease the adjustment
value 1 level at a time from the current value. If there is no improvement
after the value is decreased by 1 level, decrease by 1 level again. If there
is still no improvement, return the setting to the original value.
For details, refer to MC (Main charger output setting) on page 4-89.
The altitude is 1500 m or higher and
irregular horizontal white lines appear in
the image.
Run [Altitude Adj.] and set the adjustment value to High 1. If there is no
improvement when the value is set to High 1, set to High 2.
For details, refer to Altitude Adj. (Altitude adjustment setting) on page 4-88.
The altitude is 1500 m or higher and dots
appear in the image.
Run [Altitude Adj.] and set the adjustment value to High 1. If there is no
improvement when the value is set to High 1, set to High 2.
For details, refer to Altitude Adj. (Altitude adjustment setting) on page 4-88.
Printed Results