0 grounding instructions continued, 0 prepare unit for use, 0 base with vacuum components – Sandia 12-Gallon, 1200 PSI Hard Surface Extractor User Manual
Page 7
(34) 1200 PSI Hard Surface Extractor
1200 PSI Hard Surface Extractor (7)
2.0 Grounding Instructions Continued
the equipment. If the plug will not fit into the outlet, have a proper outlet installed by a
qualified electrician.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian
Electrical Code.
3.0 Prepare Unit for Use
DO NOT USE ON WET SURFACES. DO NOT EXPOSE TO RAIN. STORE
INDOORS.
• All Hard Surface Extractors, no matter what the time of year, are shipped with
antifreeze in the solution lines. Prior to first use, fill the tank with one quart of warm
water. Attach the hose and using the hand tool wand, flush out the system by spraying
the one quart of water through the pump.
• Attach the 1-1/2 inch vacuum hose and the brass quick disconnect.
• Fill the base unit (the recovery tank must be removed) with warm water (less than
100 degrees Fahrenheit). Fill to approximately 4 inches from the top. Use a liquid
detergent made for carpet cleaning or upholstery. Read and mix to the dilution ratios
as directed.
3.1 Automatic Chemical Feed
WARNING: THE HARD SURFACE EXTRACTOR IS DESIGNED FOR US
WITH WATER-BASED CLEANING SOLUTIONS, SUCH AS LOW-FOAMING
DETERGENTS OR ACID RINSES. Never use dry solvent solutions. The use of
dry solvents in your extractor will void the warranty.
Chemical Metering:
the Hard Surface Extractor is equipped with an automatic
water fill/chemical feed metering system. As the solution tank fills with water, cleaning
concentrate is drawn into the solution tank at a designated rate, via metering tip. A
complete set of metering tips are
included.
Metering Tip Replacement:
to adjust the amount of cleaning
concentrate being drawn, simply
remove the plastic supply tube from
the chemical feed metering valve
(Figure 1). Unscrew the colored
metering tip and replace with the
tip that corresponds to the portable
dilution ratio for your cleaning
product (Figure 2).Reconnect the
plastic supply tube.
12.0 Base with Vacuum Components
Schematic Drawing