beautypg.com

0 grounding instructions continued, 0 prepare unit for use, 0 base with vacuum components – Sandia 12-Gallon, 1200 PSI Hard Surface Extractor User Manual

Page 7

background image

(34) 1200 PSI Hard Surface Extractor

1200 PSI Hard Surface Extractor (7)

2.0 Grounding Instructions Continued

the equipment. If the plug will not fit into the outlet, have a proper outlet installed by a

qualified electrician.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian

Electrical Code.

3.0 Prepare Unit for Use

DO NOT USE ON WET SURFACES. DO NOT EXPOSE TO RAIN. STORE

INDOORS.

• All Hard Surface Extractors, no matter what the time of year, are shipped with

antifreeze in the solution lines. Prior to first use, fill the tank with one quart of warm

water. Attach the hose and using the hand tool wand, flush out the system by spraying

the one quart of water through the pump.

• Attach the 1-1/2 inch vacuum hose and the brass quick disconnect.
• Fill the base unit (the recovery tank must be removed) with warm water (less than

100 degrees Fahrenheit). Fill to approximately 4 inches from the top. Use a liquid

detergent made for carpet cleaning or upholstery. Read and mix to the dilution ratios

as directed.

3.1 Automatic Chemical Feed

WARNING: THE HARD SURFACE EXTRACTOR IS DESIGNED FOR US

WITH WATER-BASED CLEANING SOLUTIONS, SUCH AS LOW-FOAMING

DETERGENTS OR ACID RINSES. Never use dry solvent solutions. The use of

dry solvents in your extractor will void the warranty.
Chemical Metering:

the Hard Surface Extractor is equipped with an automatic

water fill/chemical feed metering system. As the solution tank fills with water, cleaning

concentrate is drawn into the solution tank at a designated rate, via metering tip. A

complete set of metering tips are

included.
Metering Tip Replacement:

to adjust the amount of cleaning

concentrate being drawn, simply

remove the plastic supply tube from

the chemical feed metering valve

(Figure 1). Unscrew the colored

metering tip and replace with the

tip that corresponds to the portable

dilution ratio for your cleaning

product (Figure 2).Reconnect the

plastic supply tube.

12.0 Base with Vacuum Components

Schematic Drawing