1.0 Safety Instructions Continued
• DO NOT leave machine outdoors, in extreme heat or cold. Harsh weather elements
will damage components and void warranty.
• Lift using only the appropriate handles.
• Always wear the appropriate clothing and safety equipment when operating the
machine.
• Keep all body parts, hair and loose clothing away from openings and moving parts.
• Use extra care when cleaning stairs. DO NOT move unit up or down stairs when tanks
are full of water. Drain solution and recovery tanks before moving unit up or down
stairs.
• Water may spill, drip or be exhausted from vacuums during operation. Place unit in an
area where water will not cause damage or use a drop cloth to protect surfaces.
• DO NOT use Citrus Acid, Buterol or harsh degreasers inside the machine.
• Use common sense to protect yourself and others from injury when using the machine.
2.0 Grounding Instructions
DANGER: IMPROPER GROUNDING METHOD CAN RESULT IN A RISK OF
ELECTRIC SHOCK.
Electrical equipment must be grounded. If the machine should malfunction or breakdown,
grounding provides a path of least resistance for electrical current to reduce the risk of
electric shock. The machine is equipped with a cord containing a grounding conductor
and grounding plug. The plug must be inserted into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
If repair or replacement of the cord or plug is necessary, DO NOT connect the grounded
wire to a flat bed terminal. The grounding wire is the wire with insulation and an outer
green surface, with or without yellow stripes.
Grounding Method
The Hard Surface Extractor is designed to run on a 20 Amp
circuit (use Cord 1, the right-
hand cord, found by standing behind the machine). 20 Amp circuits are normally found in
kitchens and bathrooms. If a circuit breaker trips during operation, reset the breaker and
move the electrical cord to a different outlet to resume operation.
The equipment is for use on a normal 120 Volt circuit. It includes a grounded plug
(shown in Figure A). A temporary adapter (Figure B and C) may be used to connect this
plug into a 2-pole receptacle (Figure B) if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet
(Figure A) can be installed by a qualified electrician. The green colored rigid ear lug or
the like extending from the adapter must be connected to a permanent ground, such as a
properly grounded outlet box cover. Whenever an adapter is used, it must be held in place
by a metal screw.
WARNING:
Improper connection of the equipment grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service person if you are in doubt as to
whether the outlet is properly grounded. DO NOT modify the plug provided with
12.0 Base with Vacuum Components
Parts List
Drawing No. Item No.
Item Description
Quantity
A
10-0848-B
1-1/2” 90 Degree ABS Street Elbow
3
B
SN-12-MFLD Extractor Motor Manifold
2
C
80-0003-A
1-1/2” Black Lined Gray Hose
2
D
10-0419-A
Screw for Extractor Hatch
12
E
10-0822
Exhaust Grate for Extractor
3
F
10-0836
19” Axle for Extractor
1
G
10-0807
Wheels for Extractor
2
H
10-0820
End Cap for Rod on Extractor
4
I
10-0808
Caster for Extractor
2
J
10-0816
Caster Bolt 1/4-20 x 1/2 Hex Bolt
8
K
10-0816
Part of Caster Bolt
L
10-0155
Hose Cuff Straight
1
N
T-A001
Cooling Duct
2
O
10-0811
2-Stage Extractor Motor
1
P
10-0833-L
Manifold Bolt 10-32 x
1/4” Hex Socket Head Cap Screw
6
Q
10-0204
Motor Mount Back-Up Washer
6
R
80-0116
Spacer for 3-Stage Extractor Motor
6
S
10-0810
3-Stage Extractor Motor
1
T
10-1030-S3
3-Stage Extractor Motor Gasket
1
U
10-1030-S2
2-Stage Extractor Motor Gasket
1