Warning – RIGOL DS6000 Series User Manual
Page 10

-8-
CAUTION
1) Please use function signal generator to output 20 Vp-p, 200 Hz square waveform.
2) Non-professionals do not adjust the Hole 2 and Hole 3.
3) This product is already adjusting Hole 2 and Hole 3. Please feel free to operation.
4) Use the adjust bar attached only.
5) When the measuring frequency was 40MHz up, you must replace the long earth
lead with the Alligator Clip (BP-276N-D) to obtain a best earth and the best
frequency response.
5. Warning
1) Do not attempt to take the ground of test equipment away from the ground
terminal.
The ground connection is critical to the safety operation of the probe. Failure to
make this connection may result in personal injury or damage to the probe or
oscilloscope. You must be sure to connect the ground before the probe tip comes
into contacting with the high voltage. And the ground connection must not be
removed until the probe tip has been taken away from the high voltage source.
2) Do not connect the ground clip to the high voltage source or the probe tip to the
ground for any reason.
3) Before turning the high voltage on, make sure that no part of your body is in
contact with the device.
4) Remembering that the voltage being measured is 1000 times greater than the
Adjust the frequency
response of the probe to
match your oscilloscope by
the adjust bar attached only.
For 40MHz up
Measuring Frequency
Hole 2.
for 200kHz Square
Wave Adjustment
Hole 3.
for Bandwidth
Adjustment
Hole 1.
for 200Hz Square Wave Adjustment