Terminal block wiring – RISCO Group ProSYS EV User Manual
Page 13

Voice Module Installation Guide 13
NOTES:
Do not run wires close to power (110/230 VAC), high-voltage wiring or 
any communication lines. 
Do not wrap or roll wires. 
All unused wires should be grounded by connecting them to the COM 
terminal. 
The maximum distance between each MBU and the Voice Module 
should not exceed 150 meter.
MBU Connection Modes
The MBU can be connected to the Voice Module in the 
following three modes: 
Ø 
Messaging mode
Ø
Listen - In mode
Ø
Listen - In & Messaging mode
Terminal Block Wiring
The following table lists the connections that should be made 
between the Voice module terminal block and the MBU terminal 
block. 
NOTES
It is recommended to mount at least one Message Box Unit (MBU) that 
has buttons close to the keypad for easy messages recording.
Voice Module
Terminal
MBU
Terminal
Description
AUX
AUX
COM
COM
12 VDC that supplies power 
to the MBU. 
NOTE:
All the AUX and COM terminals are connected in parallel.
LED LED
Controls the MBU's LED 
indicator. 
TMP TMP
The tamper terminal informs the
software when the MBU is 
opened. 