RISCO Group LightSYS 2 Supplement V3.0x User Manual
Page 4

Item
Grade 2
Enhanced
Features
Explanation
USER CODES
4 digits
6 digits
NOTE: changing the number of code digits will
require re-defining all current user codes.
ANTI CODE RESET 4 digits
6 digits
EVENT LOG
250 events 500 events
LightSYS2 always supports 512 events
INSTALLER
TAMPER
Not
required
For enhanced mode, the system control bit “ENGR.
TAMPER” shall be defined as YES.
Menu = [Programming][System][Controls][Advanced]
YES: A Tamper event causes a Lockout condition
which can only be reset by the Installer code or
by Anti-Code.
NO: A Tamper event does not cause a Lockout
condition
TROUBLE RESET
Not
required
For enhanced mode, the system control bit “Rest
Trouble” shall be defined as YES.
Menu = [Programming][System][Controls][EN50131]
YES: A System Trouble condition must be
acknowledged by the user
NO: A System Trouble condition will reset
automatically when clear
DETECTOR MASK
AND TROUBLE
Not
required
For enhanced mode, triple end-of-line termination is
supported to identify detector masking and trouble
(trouble for all Grades).
INHIBIT KEYPAD
Not
required
For enhanced mode, 10 invalid code entry attempts
will lock the keypad for 90 seconds (relevant for all
user codes and operations – arming, disarming, etc.)
DUAL PATH
ARMING
PREVENTION
Required
If there is a communication fault with the
monitoring station (by PSTN, TCP/IP, GSM, or STU)
the panel will not be ready to arm.
© RISCO Group, 12/2014. All rights reserved.
5IN2164 C
TRIPLE EOL ZONE INPUT