Servicing the meter ( service ), Batt, Clean – Precision Digital PD6830 User Manual
Page 47: Sleep
![background image](https://www.manualsdir.com/files/858290/content/doc047.png)
PD6830 Pulse Input Rate/Totalizer Instruction
Manual
47
Servicing the Meter (SERVICE)
The Service menu is used to access features used for maintenance. It is
Select
batt to backup the current total into nonvolatile memory and prepare for
a battery swap. Once this is selected, the display will flash Chang BATTERY al-
lowing up to 5 minutes for battery removal before it will automatically exit the
menu and return to run mode.
Select
Sleep to enter low power sleep mode. In sleep mode, the display elec-
tronics power down to prolong battery life. Incoming pulses are ignored in this
mode. The display and output returns to normal operation with the press of a
mechanical button, SafeTouch
®
button, or external reset contact.
!
CAUTION
The 4-20 mA transmitter output continues at the level it was last
updated before sleep mode was entered.
Select
CLEAN from the service menu to temporarily disable the SafeTouch
®
but-
tons to prevent inadvertent use. Buttons will automatically resume operation af-
ter 60 seconds. The display blinks the message CLEAN SERVICE. This should be
used when cleaning the window and when installing or removing the cover while
power is applied (in a safe area only). The clean feature is not shown in the
menu when the SafeTouch
®
buttons are disabled using the slide switch located
on the connector board.
SERVICE
BATT
SERVICE
CLEAN
SERVICE
SLEEP
SERVICE