MEDC Weatherproof ResistTel IP User Manual
Page 17

Short Manual ResistTel IP2 / IP152
Page 17
ExResistTel IP2 / IP154
The LAN-lead wire has to be connected to the connector in the front. Die LAN lead 
wire can to be with PoE (Power over Ethernet). Alternatively the phone can be 
supplied with power external. 
The second LAN connector of the ResistTel IP2 / IP152 is a blind connector closed 
with a protective cap to preserve the IP66 degree of protection 
All not used cable feed through have to be closed with sealing plugs.
Caution
You can use PoE (Power over Ethernet) or an external connection to supply the 
ResistTel IP2 / IP152 with power. 
Don’t use both at the same time, to prevent damage to the equipment.
1.5.1.3
Version with Switch LAN Module with two LAN 
Connections with Cable Screw Caps 
The telephone has in this version two internal LAN-connections with a cable screw 
cap. For the connection the LAN cable must be pulled through the cable screw cap. 
Inside the phone the female LAN connection from Tycoelectronics (AMP) has to be 
pressed on the cable (Refer to chapter 1.4 beginning on page 10). A female LAN 
cable connector belongs to the as-delivered condition. With the inside the phone 
existing little LAN connection cable, the LAN can be connected with the phone. 
The LAN1 delivery can be available with PoE (Power over Ethernet). Alternatively the 
phone can be supplied with power external. 
The LAN2 delivery doesn’t support PoE. Also it can’t be used to connect a phone 
directly, which should be powered with PoE. 
All not used cable feed through have to be closed with sealing plugs.
1.5.1.4
Version with Switch LAN Module with two LAN 
Connections with two Female Housing Connections 
The phone has in this version two LAN-connections with a female LAN connection at 
the housing. LAN-cable, used for plug into the telephone ResistTel IP2 / IP152, have 
to be adapted with a connector from Phoenix contact (Refer to chapter 1.4 beginning 
on page 10), to preserve the IP66 degree of protection. A LAN cable connector 
belongs to the as-delivered condition. 