Installation recommendations in compliance with UNI 10683
Technical dept. - All rights reserved by MCZ GROUP S.p.A. - Reproduction
prohibited
in the case of ducting, up to 3.5 linear metres, increase the
cross-section by about 5% whereas for longer ducter, increase it
by 15%.
Remember that the ventilation grilles always feature an
indication of the useful cross-section in cm
2
on one side.
When choosing the grille and hole size, check that the useful
cross-section of the grille is larger or the same as the cross-
section required by MCZ for the appliance operation.
IMPORTANT!
The flow of air may also be taken from an adjoining
room to the one in which the stove is installed,
provided the air can flow freely through permanent
apertures communicating with the outside; avoid air
inlets connected to thermal power plants, garages,
kitchens or bathrooms.