MCZ Hydrotherm 70 User Manual
Page 18

INSTALLATION AND USE MANUAL
Chapter 4
page
18
Installation and assembly
Technical service – MCZ GROUP S.p.A. all rights reserved - Reproduction prohibited
25
80
100
80
100
80
10
0
For installation near flammable material, comply with the following
minimum safe distances:
Distance from the sides and back= 100 mm
Height above floor = 80 mm
Insulating material on sides and back= 80 mm
Insulating material on the floor = 25 mm
If the stove is positioned over a floor or close to
walls made of flammable materials, it is advisable to
use sufficient insulation.
The hot air outlets must be placed at least 300 mm
from other materials (e.g. curtains)
4.3. HEIGHT ADJUSTMENT
The Hydrotherm fireplace stove is equipped with adjustment feet,
whose purpose is to allow the easy levelling of the fire bed. The feet
allow an adjustment of about 6-7 cm and are mounted on the pre-set
brackets (See figure)
If you want to raise the fireplace stove by more than 6-7 cm, you need
to create a masonry pedestal to set the product on. Do not eliminate
the feet. They are indispensable for levelling.
If the fireplace stove is not placed level, there is the
risk that door will not close perfectly, and that the
internal counterweights strike the structure, causing
noise each time the door is raised or lowered.
It is possible to adjust the levelling of the fireplace
stove by checking the sliding of the door until it no
longer makes any noise.
4.4. RELEASE OF COUNTERWEIGHTS
The fireplace stove is delivered with the sliding counterweights locked
in place. In this way, during shipping and handling, they will not strike
and damage the sliding parts, the door and the ceramic glass.
To release the counterweights and therefore also the door, remove the
screws as shown in
figure 2 from both sides of the fireplace stove.
Remove the screws that hold the counterweights
only after you have positioned the fireplace stove
and to ensure that the glass is in good condition.
DO NOT MOVE THE FIREPLACE STOVE WITHOUT THE
SCREWS THAT HOLD THE COUNTERWEIGHTS.
Damage caused by failure to observe this rule is the
responsibility of the client or his representative.